Adcraft JD-1 Instruction Manual Download Page 10

November 2018

 

 

 

 

 

 

 

TROUBLE SHOOTING:

 

Wait 30 seconds before removing the panels so 

that 

all the moving parts inside the 

machine will be stopped

.

 

 

Symptom

 

Cause

 

Solution

 

 

No power to 

machine

 

• 

Plug 

is 

not 

in

 

•  Main switch 

is 

not to set 

to the [ON] position 

• 

Feeder cable 

is 

broken

 

• 

Ma

i

n switch is broken

 

•  Insert plug

 

•  Switch main switch to  [ON]

 

 

•  Replace feeder cable

 

•  Replace main switch

 

 

 

 

Machine is not 

cooling

 

• 

Compressor does not 

start

 

•  Gas leak 

into 

the cooling 

circuit 

 

•  Condenser is clogged 

• 

Fan motor 

is 

burnt

 

• 

Lack of air flow

 

•  See "compressor does not 

start

section 

•  Find leak

Filter 

it 

out and 

re-charge the cooling circuit

 

•  Clean 

the 

condenser 

• 

Replace 

fan 

motor

 

•  Increase distance between the 

machine and other obstacles 

/heating 

sources

 

 

 

Compressor does 

not start

 

• 

Main switch is broken

 

• 

Compressor protector 

is

 

broken

 

• 

Compressor relay 

is

 

broken

 

• 

Compressor motor 

is

 

broken

 

 

• 

Replace main switch

 

• 

Replace compressor  protector

 

 

• 

Replace compressor relay

 

• 

Replace motor

 

 

 

 

 

One bowl is not 

cooling

 

• 

Gas leak into 

the 

cooling 

circuit

 

• 

Condenser 

is 

clogged

 

• 

Lack of air flow

 

 

 

• 

Tube of the cooling circuit 

is clogged

 

•  Filter is clogged 

• 

Find leak

Filte

it 

out and

 

re-charge 

the 

cooling circuit

 

 

• 

Clean the condenser

 

• Increase distance between the 

machine and other  obstacles 

/heating 

sources

 

• 

Cut 

the 

tube

Eliminate clog

,

 

re-charge the cooling circuit

 

•  Replace the filter 

The mixing paddles 

are not working

 

•  The mixing motor 

is

 

broken

 

•  Replace 

the 

mixing motor

 

The pump 

is 

not 

working

 

• 

The pump motor 

is 

broken

 

• 

The pump sw

i

tch 

i

broken

 

 

 

 

•  Replace the pump motor 

• 

Replace the pump switch

 

Summary of Contents for JD-1

Page 1: ...your Adcraft unit Please read this manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidelines outlined in this manual may void the war...

Page 2: ...electrical cord when unplugging the machine The company reserves the right to modify the construction or appearance without notice INSTALLATION Useful instruction for transport 1 In order to prevent t...

Page 3: ...pliance with current safety standards If in doubt consult only specialized technicians By law the machine must always be grounded HOW TO USE Before use the dispenser should be cleaned carefully as it...

Page 4: ...move the power plug b Do not use abrasive powders that might impair bowls and the lid s shine c Use neutral soap and a little warm water to wash container lid mixing paddles pump refrigerator tank and...

Page 5: ...it from its setting f To disassemble the back and side panels loosen the screws under the unit pushing up and then unlatch g To disassemble front panel loosen the side screws To reassemble the unit re...

Page 6: ...November 2018 TECHNICAL SPECIFICATIONS...

Page 7: ...November 2018...

Page 8: ...November 2018 OPERATING FIGURES...

Page 9: ...November 2018 OPERATING FIGURES...

Page 10: ...en the machine and other obstacles heating sources Compressor does not start Main switch is broken Compressor protector is broken Compressor relay is broken Compressor motoris broken Replace main swit...

Page 11: ...November 2018 November 2018 Structure Diagram Structural Diagram...

Page 12: ...delivery or installation fire flood riot or act of God Equipment that has the model number or serial number removed or altered Equipment on which the security seal has been broken If the equipment ha...

Reviews: