background image

10/08

 

 

105715AE

 

OmniReach

®

 FTTX 

Solutions

OmniReach

®

 FTTX Solutions

RealFlex™ MDU Drop Cables

2

w w w . a d c . c o m  

•  

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  

•  

1 - 8 0 0 - 3 6 6 - 3 8 9 1

Features and Benefits

Bend radius as small as 7.5 mm without changing 

• 

cable characteristics

Greatly reduces risk to bend induced insertion  

• 

loss created during installation

Indoor/Outdoor, Plenum and Riser cable  

• 

options available

Rugged 3 mm cable jacket construction

• 

G.657 Table A and B compliant

• 

Two cable configurations available: connectors  

• 

on both ends or connector on one end

Spooling options: end with connector pulled first 

• 

or end without connector pulled first

Ivory cable color helps distinguish cable  

• 

in the field

Specifications

environmental CharaCteristiCs 

indoor/outdoor Cable

1

 

riser Cable 

Plenum Cable

storage temperature:

 

-40° to +75° C 

-40° to +70° C 

-40° to +70° C

      

(-40° to +167° F) 

(-40° to +158° F) 

(-40° to +158° F)

operating temperature:

 

-40° to +75° C 

-20° to +70° C 

0° to +70° C

      

(-40° to +167° F) 

(-4° to +158° F) 

(+32° to +158° F)

installation temperature:

 

-30° to +50° C 

0° to +50° C 

+10° to +50° C

      

(-22° to +122° F) 

(+32° to +122° F) 

(+50° to +122° F)

meChaniCal CharaCteristiCs 

indoor/outdoor,  

      

riser and Plenum Cable

number of Fibers:

 

1

maximum tensile load
  short term load:

 

440 N (100 lbs.)

  long term load:

 

220 N (50 lbs.)

minimum Bend radius
  installed:

 

.295 in. (.75 cm)

  loaded:

 

1.18 in. (3.0 cm)

1

 For cable lengths that are ten feet or less, the Storage and Operating Temperature specifications are -55º to +75º C  

  (-67 to +167º F

)

reference

1550 nm

standard Fiber

dBr

reduced Bend radius Fiber

stapled 3mm realFlex™ mDU Drop Cables

Summary of Contents for RealFlex Drop Cables

Page 1: ...ce the rugged 3mm cable construction provides the flexibility and durability to withstand the most demanding applications The rugged 3 mm indoor outdoor cable can be stapled allowing for fast and easy securing of cables to most surfaces The reduced bend radius glass allows the technician to staple around tight corners without compromising insertion loss performance ADC s RealFlex MDU Drop Cables p...

Page 2: ...s distinguish cable in the field Specifications environmental Characteristics Indoor Outdoor Cable1 Riser Cable Plenum Cable Storage Temperature 40 to 75 C 40 to 70 C 40 to 70 C 40 to 167 F 40 to 158 F 40 to 158 F Operating Temperature 40 to 75 C 20 to 70 C 0 to 70 C 40 to 167 F 4 to 158 F 32 to 158 F Installation Temperature 30 to 50 C 0 to 50 C 10 to 50 C 22 to 122 F 32 to 122 F 50 to 122 F MECH...

Page 3: ...ia GR 20 tested to relevant specifications X X ISO IEC 11801 X X X IEC 60794 2 Optical Fiber Cables Part 2 X EIA TIA 568 B X X X UL 1666 NEC OFNR FT 4 X X UL 910 NEC OFNP FT 6 X Catalog Number MDC __ __ __ __ __ __ __ __ __ __ Spool Option 0 No Spool J Standard Spool F Spooled Connector First L Spooled Connector Last Standard Cable Measurement F Feet M Meters Connector 1 Type J APC SC N UPC SC Con...

Page 4: ...ion of this document Because we are continuously improving our products ADC reserves the right to change specifications without prior notice At any time you may verify product specifications by contacting our headquarters office in Minneapolis ADC Telecommunications Inc views its patent portfolio as an important corporate asset and vigorously enforces its patents Products or features contained her...

Reviews: