10/08
•
105715AE
OmniReach
®
FTTX
Solutions
OmniReach
®
FTTX Solutions
RealFlex™ MDU Drop Cables
2
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Features and Benefits
Bend radius as small as 7.5 mm without changing
•
cable characteristics
Greatly reduces risk to bend induced insertion
•
loss created during installation
Indoor/Outdoor, Plenum and Riser cable
•
options available
Rugged 3 mm cable jacket construction
•
G.657 Table A and B compliant
•
Two cable configurations available: connectors
•
on both ends or connector on one end
Spooling options: end with connector pulled first
•
or end without connector pulled first
Ivory cable color helps distinguish cable
•
in the field
Specifications
environmental CharaCteristiCs
indoor/outdoor Cable
1
riser Cable
Plenum Cable
storage temperature:
-40° to +75° C
-40° to +70° C
-40° to +70° C
(-40° to +167° F)
(-40° to +158° F)
(-40° to +158° F)
operating temperature:
-40° to +75° C
-20° to +70° C
0° to +70° C
(-40° to +167° F)
(-4° to +158° F)
(+32° to +158° F)
installation temperature:
-30° to +50° C
0° to +50° C
+10° to +50° C
(-22° to +122° F)
(+32° to +122° F)
(+50° to +122° F)
meChaniCal CharaCteristiCs
indoor/outdoor,
riser and Plenum Cable
number of Fibers:
1
maximum tensile load
short term load:
440 N (100 lbs.)
long term load:
220 N (50 lbs.)
minimum Bend radius
installed:
.295 in. (.75 cm)
loaded:
1.18 in. (3.0 cm)
1
For cable lengths that are ten feet or less, the Storage and Operating Temperature specifications are -55º to +75º C
(-67 to +167º F
)
reference
1550 nm
standard Fiber
dBr
reduced Bend radius Fiber
stapled 3mm realFlex™ mDU Drop Cables