background image

Spec 

Sheet

Website: www.adc.com

From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080 

Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.

ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota  USA  55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously 
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may 
verify  product  specifications  by  contacting  our  headquarters  office  in  Minneapolis.  ADC  Telecommunications,  Inc. 
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features 
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer

105715ae  10/08  revision  ©  2008, 2007  aDC telecommunications, inc.  all rights reserved

Summary of Contents for RealFlex Drop Cables

Page 1: ...ce the rugged 3mm cable construction provides the flexibility and durability to withstand the most demanding applications The rugged 3 mm indoor outdoor cable can be stapled allowing for fast and easy securing of cables to most surfaces The reduced bend radius glass allows the technician to staple around tight corners without compromising insertion loss performance ADC s RealFlex MDU Drop Cables p...

Page 2: ...s distinguish cable in the field Specifications environmental Characteristics Indoor Outdoor Cable1 Riser Cable Plenum Cable Storage Temperature 40 to 75 C 40 to 70 C 40 to 70 C 40 to 167 F 40 to 158 F 40 to 158 F Operating Temperature 40 to 75 C 20 to 70 C 0 to 70 C 40 to 167 F 4 to 158 F 32 to 158 F Installation Temperature 30 to 50 C 0 to 50 C 10 to 50 C 22 to 122 F 32 to 122 F 50 to 122 F MECH...

Page 3: ...ia GR 20 tested to relevant specifications X X ISO IEC 11801 X X X IEC 60794 2 Optical Fiber Cables Part 2 X EIA TIA 568 B X X X UL 1666 NEC OFNR FT 4 X X UL 910 NEC OFNP FT 6 X Catalog Number MDC __ __ __ __ __ __ __ __ __ __ Spool Option 0 No Spool J Standard Spool F Spooled Connector First L Spooled Connector Last Standard Cable Measurement F Feet M Meters Connector 1 Type J APC SC N UPC SC Con...

Page 4: ...ion of this document Because we are continuously improving our products ADC reserves the right to change specifications without prior notice At any time you may verify product specifications by contacting our headquarters office in Minneapolis ADC Telecommunications Inc views its patent portfolio as an important corporate asset and vigorously enforces its patents Products or features contained her...

Reviews: