Alarms
350-200-115-02, Issue 2
14
September 25, 1998
HLU-200 List 1E
PWR FEED OFF Power Feed Off
HDSL span power has been turned off by
setting the PWFD option to DIS or HDSL span
power has been turned off by use of the
A1LB/A2LB/A5LB Intelligent Office Repeater
(IOR) Power Down code.
PWR FEED
GND
Power Feed Ground
One of the HDSL loops has been grounded.
BER
Bit Error Rate
A system BER alarm is in effect.
BAD RT?
No response from
HRU
The HLU does not receive any
response from the HRU. Thus, the HRU
integrity is questionable.
VER
HLU Software
Version #
This displayed during the System
Settings review mode. Depress the MODE
button for 3 seconds to enter System Settings
review mode.
LIST 0xL
HLU’s List #
Displayed during System Settings
review mode defined above.
FRM
Frame: SF, ESF,
UNFR, NONE
Defines the type of frame pattern
being received from the DSX-1.
Displayed during System Settings.
CODE
Line Code: AMI, B8ZS
This is the line code that the HLU is set to
receive and transmit at its T1
interfaces. Displayed during System Settings
mode defined above.
Table 4.
HLU-200 List 1E Diagnostic Messages (Cont.)
Message
Full Name
Description