Installation and Test
SCP-FCS717-042-03H
12
January 6, 2003
FCS-717 List 4B
Connect the Frame Ground
Follow the instructions below and refer to
to connect the frame ground.
1
Connect one end of the frame ground wire to the grounding lug G1 (frame ground).
2
Connect the other end of the frame ground wire to the CO ground termination point.
Figure 4.
Connecting the Frame Ground (Protection Ground)
CO battery return (RTN_A, RTN_B) is separate from frame ground in the PG-Flex
equipment.
CKT GND and CO battery return are connected inside the PG-Flex line unit but are
not connected on the backplane.
The minimum frame ground wire size is 6 AWG.
To CO Ground
Termination Point
Frame Ground
(G1)