ADC ES30/30 Installation & Operator'S Manual Download Page 3

112809 - 6

www.adclaundry.com

3

IMPORTANT

You must disconnect and lockout the electric supply and

the gas supply or the steam supply before any covers or

guards are removed from the machine to allow access for

cleaning, adjusting, installation, or testing of any equipment

per OSHA standards.
Please observe all safety precautions displayed on the

equipment and/or specified in the installation manual

included with the dryer.
Before installation, check that the local distribution

conditions, nature of gas and pressure, and adjustment of

the appliances are compatible.

CAUTION

Dryer(s) should never be left unattended while in operation.
“Caution: Label all wires prior to disconnection when

servicing controls.  Wiring errors can cause improper

operation.”
«Attention: Au moment de l’entretien des commandes,

étiquetez tous les fils avant de les débrancher.  Des erreurs

de câblage peuvent entraîner un fonctionnement inadéquat

et dangereux.»

WARNING

Children should not be allowed to play on or near the dryer(s).

Children should be supervised if near dryer(s) in operation.
Under no circumstances should the dryer door switch(es),

lint door/drawer switch(es), or heat safety circuit(s) ever

be disabled.
Do not modify this appliance.
The dryer must never be operated with any of the back

guards, outer tops, or service panels removed.  Personal

injury or fire could result.
The dryer must never be operated without the lint filter/

screen in place, even if an external lint collection system is

used.

FOR YOUR SAFETY

Do not dry mop heads in the dryer.  Do not use dryer in

the presence of dry cleaning fumes.

The dryers must not be installed or stored in an area where

it will be exposed to water and/or weather.
The wiring diagram for the dryer is located behind the control

panel.

List of Acronyms _______________________

HVAC

Heating, Ventilating, and Air-Conditioning

in WC

Inches of Water Column

L.C.D.

Liquid Crystal Display

L.P.

Liquid Propane

OSHA

Occupational Safety and Health Administration

R.M.A.

Return Material Authorization

UL

Underwriters Laboratory

Proposition 65

Use of this product could expose you to substances

from fuel combustion that contain chemicals

known to the State of  California to cause cancer,

birth defects and other reproductive harm.

Table of Contents ________________

In the State of Massachusetts, the following
installation instructions apply:

Installations and repairs must be performed
by a qualified or licensed contractor,
plumber, or gasfitter qualified or licensed by
the State of Massachusetts.

If using a ball valve, it shall be a T-handle
type.

A flexible gas connector, when used, must
not exceed 3 feet.

!

 WARNING

Safety Precautions ..................................... 4
Specifications ............................................ 6
Installation Procedures .............................. 8

Location Requirements ................................................. 8
Unpacking / Setting Up ................................................. 8
Dryer Enclosure Requirements ..................................... 8
Fresh Air Supply Requirements .................................... 9
Exhaust Requirements ................................................. 9
Electrical Information .................................................. 11
Gas Information .......................................................... 13
Converting from One Family of Gas to Another .......... 14
Gas Pressure Testing ................................................. 16
Steam Information ....................................................... 16
Water Information ....................................................... 18
Preparation for Operation / Start-Up ........................... 18
Preoperational Test .................................................... 18
Preoperational Instructions ......................................... 19
Shutdown Instructions ............................................... 19

Service / Parts Information ..................... 20

Service ...................................................................... 20
Parts .......................................................................... 20

Warranty Information ............................... 20

Returning Warranty Cards .......................................... 20
Warranty .................................................................... 20
Returning Warranty Parts ........................................... 20

Routine Maintenance ............................... 21

Cleaning ..................................................................... 21
Adjustments ............................................................... 21

Data Label Information ............................ 22
Programming ............................................ 23

Summary of Contents for ES30/30

Page 1: ...urnisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explo...

Page 2: ...____________________________________________________ _______________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or the ADC factory When ordering replacement parts from the factory you can FAX your order toADC at 1 508 678 9447 or telephone your order directly to theADC Parts Department at 1 508 678 90...

Page 3: ...cleaning fumes The dryers must not be installed or stored in an area where it will be exposed to water and or weather Thewiringdiagramforthedryerislocatedbehindthecontrol panel List of Acronyms _______________________ HVAC Heating Ventilating and Air Conditioning in WC Inches of Water Column L C D Liquid Crystal Display L P Liquid Propane OSHA Occupational Safety and Health Administration R M A Re...

Page 4: ...that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should be established for the inspection and cleaning of lint in the burner a...

Page 5: ...____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ The cool down cycle of tumble dryers should be used to reduce the temperature of the items ...

Page 6: ...6 15 24 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 3 8 M N P T 3 8 M B S P T CE and Australia Only VOLTAGE AVAILABLE N A APPROXIMATE NET WEIGHT APPROXIMATE SHIPPING WEIGHT AIRFLOW PER POCKET EXHAUST CONNECTION DIAMETER PER POCKET COMPRESSED AIR CONNECTION COMPRESSED AIR VOLUME OVEN SIZE PER POCKET kW Btu hr kcal hr VOLTAGE AVAILABLE N A APPROXIMATE ...

Page 7: ...claundry com 7 Specifications _______________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation ...

Page 8: ... venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combustible lint and must be exhausted to the outdoors Every 6 months inspect the exhaust ...

Page 9: ...ested that the use of 90 turns be avoided use 30 and or 45 bends instead The radius of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint fro...

Page 10: ... this ductwork must be at least 8 inches 20 32 cm even though the dryer exhaust duct connection is smaller Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than four 90 elbows should be used in the exhaust duct run If more than the equivalent of four 90 elbows are used the cross sectional area of the ductwork must be increased Multiple Dryer ...

Page 11: ...lation If the nominal voltage is outside of the medium tolerances shown on the diagram below adjust the autotransformers located near the burner TERM LINE VOLTAGE 50 Hz 60 Hz HIGH 260 226 283 249 MED 239 208 260 230 LOW 217 189 236 208 10 20 14 Electric Models Only All electrically heated dryers must be connected to the electric service shown on the dryer s data label The connecting wires must be ...

Page 12: ...ded in this box To gain access the service box cover must be removed Gas and Steam Models Only 120 240V Application with Neutral Input connection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s data label IMPORTANT A strain relief must be used where the input wiring enters the oven assembly Electrically Heated Models Only The electrical i...

Page 13: ...d If this information does not agree with the type of gas available do not operate the dryer Contact the reseller who sold the dryer or contact the manufacturer The input ratings shown on the data label are for elevations up to 2 000 feet 610 meters unless elevation requirements of over 2 000 feet 610 meters were specified at the time the dryer order was placed with the factory The adjustment or c...

Page 14: ... liquid detergent works well Warning Never test for leaks with a flame Converting from One Family of Gas to Another ______________________ Warning CE Dryers This appliance must only be operated with the gas type indicated on the dryer s data plate If the appliance is converted gas type changed a data plate amendment must be obtained from American Dryer Corporation dryer s serial number is required...

Page 15: ...he cap with blocking pin and install the regulator vent cap from the kit ADC P N 140415 Converting from unregulated L P to unregulated natural gas no change to the regulator is required Converting from regulated L P to regulated natural gas remove the white plastic regulator adjustment screw under vent cap Remove spring under screw and replace with spring from kit ADC P N 140415 Replace regulator ...

Page 16: ... steam will cause water hammer and subsequent heat exchanger failure The steam supply connection must be taken from the top of a well dripped steam main If the supply run out to the dryer exceeds 25 feet 7 6 meters it should be dripped just before the control valve with a proper trap and dirt pocket IMPORTANT Failure to comply with the requirements stipulated in this manual can result in component...

Page 17: ...ryer must include a 12 inch 30 48 cm riser along with a drip trap and check valve This will prevent any condensate from entering the steam coil Flexible hoses or couplings must be used The dryer vibrates slightly when it runs and this will cause the steam coil connections to crack if they are hard piped to the supply and return mains Shutoff valves for each dryer should be installed in the supply ...

Page 18: ...e at the cross or four way fitting located in the outlet supply side of the water solenoid valve The manual ball cock shutoff valve must be located outside of the dryer at a distance from the dryer where it is easily accessible The use and connection of this manual bypass is at the option or discretion of the owner The water connection for the manual bypass is made to the cross or four way fitting...

Page 19: ...rt XX XX amount to Start Insert coin s Once the correct Amount to Start has been inserted the L C D will display Select Temperature Select temperature by pressing HI MED or LO The cycle will start and the L C D will display the Dry Cycle selected and the remaining time The dryer will continue through the drying and cooling cycles until the vended time has expired NOTE To stop the dryer open main d...

Page 20: ...e factory for warranty information be sure to have the dryer s model number and serial number available so that your inquiry can be handled in an expeditious manner Returning Warranty Parts All dryer or parts warranty claims or inquiries should be addressed to the Warranty Parts Department To expedite processing the following procedures must be followed No parts are to be returned without prior wr...

Page 21: ...eekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area Warning To avoid the hazard of electrical shock discontinue electrical supply to the dryer Steam Dryers Clean the steam coil fins It is suggested that compressed air and a vacuum cleaner with brush attachment be used Warning When cleaning steam coil fins be careful not to bend the fins If fins are...

Page 22: ...l Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or L P gas electric or steam 4 Heat Input For Gas Dryers This describes the heat input in British thermal units per hour Btu hr or kilowatts kW 5 Orifice Size For Gas Dryers Gives the number drill size used 6 Electric Servic...

Page 23: ...oin 1 input E8 This indicates a bad coin pulse was detected on coin 2 input E9 EB Upper Lower forward pocket rotation fault count EA EC Upper Lower reverse rotation fault count ED S A F E DISABLED Water not connected Factory Settings Definitions RADIANT TIMEOUT During an attempt to start the burner this parameter sets the maximum wait time for the radiant sensor to cool and close circuit A failure...

Page 24: ...ADC Part No 112809 6 10 21 14 ...