Gas Information _______________________

It is your responsibility to have all plumbing connections,
materials, and workmanship conform to local and state
regulations or codes of the country of destination.  In the
absence of such codes, all plumbing connections, materials,
and workmanship must conform to the applicable local
requirements.  In the USA this is the National Fuel Gas Code
ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian
Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or
CAN/CGAB149.2-M91 (L.P. Gas) or LATEST EDITION.
In Australia, the fuel gas code is AS/NZS5601, local authority,
gas, electricity, and any other relevant statutory regulations.
It is important that gas pressure regulators meet applicable
pressure requirements, and that gas meters be rated for the
total amount of all the appliance Btu being supplied.

IMPORTANT: 

Failure to comply with these codes or

ordinances, and/or the requirements stipulated in this
manual, can result in personal injury and improper
operation of the dryer.
For ease of service, the individual gas supply line of each
dryer must have its own manual shutoff valve.
Failure to isolate or disconnect the dryer from supply as
noted can cause irreparable damage to the gas valve,
voiding the warranty.
The dryer and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess
of 1/2 psig (3.5 kPa) for non-CE dryers or 50 mb for CE
dryers.

NOTE:

 The dryer must be isolated from the gas supply

piping system by closing its individual manual shutoff valve
during any pressure test of the gas supply system at test
pressures equal to or less than 1/2 psig (3.5 kPa) for non-
CE dryers or 50 mb for CE dryers.

Warning

Fire or explosion could result due to failure of
isolating or disconnecting the gas supply as

noted.

!

NOTE:

 Undersized gas piping will result in ignition

problems, slow drying, increased use of energy, and can
create a safety hazard.

The dryer must be connected to the type of heat/gas indicated
on the data label and pressure must be confirmed.  If this
information does not agree with the type of gas available, do
not operate the dryer.  Contact the reseller who sold the dryer
or contact the manufacturer.
The input ratings shown on the data label are for elevations
up to 2,000 feet (610 meters), unless elevation requirements
of over 2,000 feet (610 meters) were specified at the time the
dryer order was placed with the factory.  The adjustment or
conversion of dryers in the field for elevations over 2,000 feet
(610 meters) is made by changing each burner orifice.  If this
conversion is necessary, contact the reseller who sold the
dryer or contact the manufacturer.

IMPORTANT: 

If connection to this appliance is made with a

flexible hose, it must be suitable for the appliance category
in accordance with national installation regulations of the
country of destination, and if in doubt the installer must
contact the supplier.  The manufacturer of this appliance
does not recommend the use of flexible gas supply line/
hose.  An external gas supply shutoff must be provided.

CE and Australian Dryers

There are 2 N.P.T. to B.S.P.T. adaptors included with each
dryer, which must be installed to the gas inlets.  The adaptors
are shipped in the upper tumbler.

IMPORTANT: 

Pipe joint compounds that resist the action of

natural, propane, and butane gases must be used.

Warning (CE Dryers Only)

This appliance must only be operated with the
gas type indicated on the dryer’s data plate.  If

the appliance is converted (gas type changed), a data
plate amendment must be obtained from American Dryer
Corporation for CE approved units.

Gas Connections

Inlet connection ..... 1/2” N.P.T.

3/8” B.S.P.T. (CE and Australian dryers)

Inlet supply size .... 1/2” Diameter Pipe (minimum)

Heat Input / Gas Consumption / Orifice (Injector) Data

(For Non-CE [European] and Non-AGA [Australia] Models Only)

Shaded areas are stated in metric equivalents

*

Gas valve’s internal regulator disabled.

** Information is per pocket/tumbler.
*** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Gas Specifications for Non-CE and Non-AGA Approved Dryers***

Gas Type and

Nominal Heating Value

Supply

Pressure

**Gross

Heat Input

Orifice Size

**Orifice

(Injector)

Quantity

Burner

Pressure

B tu/ft

3

in WC

Btu/hr

kW

DMS

mm

in WC

 Natural

1,000

7.0-13.0

52,500

15.37

21

4.038

1

3.0

 *Liquid Propane

2,500

11.0

52,500

15.37

45

2.082

1

10.0

Summary of Contents for ES30/30

Page 1: ...urnisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explo...

Page 2: ...____________________________________________________ _______________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or the ADC factory When ordering replacement parts from the factory you can FAX your order toADC at 1 508 678 9447 or telephone your order directly to theADC Parts Department at 1 508 678 90...

Page 3: ...cleaning fumes The dryers must not be installed or stored in an area where it will be exposed to water and or weather Thewiringdiagramforthedryerislocatedbehindthecontrol panel List of Acronyms _______________________ HVAC Heating Ventilating and Air Conditioning in WC Inches of Water Column L C D Liquid Crystal Display L P Liquid Propane OSHA Occupational Safety and Health Administration R M A Re...

Page 4: ...that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should be established for the inspection and cleaning of lint in the burner a...

Page 5: ...____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ The cool down cycle of tumble dryers should be used to reduce the temperature of the items ...

Page 6: ...6 15 24 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 3 8 M N P T 3 8 M B S P T CE and Australia Only VOLTAGE AVAILABLE N A APPROXIMATE NET WEIGHT APPROXIMATE SHIPPING WEIGHT AIRFLOW PER POCKET EXHAUST CONNECTION DIAMETER PER POCKET COMPRESSED AIR CONNECTION COMPRESSED AIR VOLUME OVEN SIZE PER POCKET kW Btu hr kcal hr VOLTAGE AVAILABLE N A APPROXIMATE ...

Page 7: ...claundry com 7 Specifications _______________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation ...

Page 8: ... venting can be achieved as noted in this manual refer to Exhaust Requirements section IMPORTANT The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber CAUTION This dryer produces combustible lint and must be exhausted to the outdoors Every 6 months inspect the exhaust ...

Page 9: ...ested that the use of 90 turns be avoided use 30 and or 45 bends instead The radius of the elbows should preferably be 1 1 2 times the diameter of the duct All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts overlap the duct being connected All ductwork joints must be taped to prevent moisture and lint fro...

Page 10: ... this ductwork must be at least 8 inches 20 32 cm even though the dryer exhaust duct connection is smaller Including tumbler dryer elbow connections or elbows used for outside protection from the weather no more than four 90 elbows should be used in the exhaust duct run If more than the equivalent of four 90 elbows are used the cross sectional area of the ductwork must be increased Multiple Dryer ...

Page 11: ...lation If the nominal voltage is outside of the medium tolerances shown on the diagram below adjust the autotransformers located near the burner TERM LINE VOLTAGE 50 Hz 60 Hz HIGH 260 226 283 249 MED 239 208 260 230 LOW 217 189 236 208 10 20 14 Electric Models Only All electrically heated dryers must be connected to the electric service shown on the dryer s data label The connecting wires must be ...

Page 12: ...ded in this box To gain access the service box cover must be removed Gas and Steam Models Only 120 240V Application with Neutral Input connection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s data label IMPORTANT A strain relief must be used where the input wiring enters the oven assembly Electrically Heated Models Only The electrical i...

Page 13: ...d If this information does not agree with the type of gas available do not operate the dryer Contact the reseller who sold the dryer or contact the manufacturer The input ratings shown on the data label are for elevations up to 2 000 feet 610 meters unless elevation requirements of over 2 000 feet 610 meters were specified at the time the dryer order was placed with the factory The adjustment or c...

Page 14: ... liquid detergent works well Warning Never test for leaks with a flame Converting from One Family of Gas to Another ______________________ Warning CE Dryers This appliance must only be operated with the gas type indicated on the dryer s data plate If the appliance is converted gas type changed a data plate amendment must be obtained from American Dryer Corporation dryer s serial number is required...

Page 15: ...he cap with blocking pin and install the regulator vent cap from the kit ADC P N 140415 Converting from unregulated L P to unregulated natural gas no change to the regulator is required Converting from regulated L P to regulated natural gas remove the white plastic regulator adjustment screw under vent cap Remove spring under screw and replace with spring from kit ADC P N 140415 Replace regulator ...

Page 16: ... steam will cause water hammer and subsequent heat exchanger failure The steam supply connection must be taken from the top of a well dripped steam main If the supply run out to the dryer exceeds 25 feet 7 6 meters it should be dripped just before the control valve with a proper trap and dirt pocket IMPORTANT Failure to comply with the requirements stipulated in this manual can result in component...

Page 17: ...ryer must include a 12 inch 30 48 cm riser along with a drip trap and check valve This will prevent any condensate from entering the steam coil Flexible hoses or couplings must be used The dryer vibrates slightly when it runs and this will cause the steam coil connections to crack if they are hard piped to the supply and return mains Shutoff valves for each dryer should be installed in the supply ...

Page 18: ...e at the cross or four way fitting located in the outlet supply side of the water solenoid valve The manual ball cock shutoff valve must be located outside of the dryer at a distance from the dryer where it is easily accessible The use and connection of this manual bypass is at the option or discretion of the owner The water connection for the manual bypass is made to the cross or four way fitting...

Page 19: ...rt XX XX amount to Start Insert coin s Once the correct Amount to Start has been inserted the L C D will display Select Temperature Select temperature by pressing HI MED or LO The cycle will start and the L C D will display the Dry Cycle selected and the remaining time The dryer will continue through the drying and cooling cycles until the vended time has expired NOTE To stop the dryer open main d...

Page 20: ...e factory for warranty information be sure to have the dryer s model number and serial number available so that your inquiry can be handled in an expeditious manner Returning Warranty Parts All dryer or parts warranty claims or inquiries should be addressed to the Warranty Parts Department To expedite processing the following procedures must be followed No parts are to be returned without prior wr...

Page 21: ...eekly Clean lint accumulation from lint chamber thermostat and microprocessor temperature sensor area Warning To avoid the hazard of electrical shock discontinue electrical supply to the dryer Steam Dryers Clean the steam coil fins It is suggested that compressed air and a vacuum cleaner with brush attachment be used Warning When cleaning steam coil fins be careful not to bend the fins If fins are...

Page 22: ...l Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or L P gas electric or steam 4 Heat Input For Gas Dryers This describes the heat input in British thermal units per hour Btu hr or kilowatts kW 5 Orifice Size For Gas Dryers Gives the number drill size used 6 Electric Servic...

Page 23: ...oin 1 input E8 This indicates a bad coin pulse was detected on coin 2 input E9 EB Upper Lower forward pocket rotation fault count EA EC Upper Lower reverse rotation fault count ED S A F E DISABLED Water not connected Factory Settings Definitions RADIANT TIMEOUT During an attempt to start the burner this parameter sets the maximum wait time for the radiant sensor to cool and close circuit A failure...