ADCP-75-210 • Issue 1 • March 2007
Page 52
© 2007, ADC Telecommunications, Inc.
4. Pull out the battery drawer.
5. Move the gravity latch to the down position. Lock the telescopic slide into the locked out
position.
6. Install the batteries in the drawer as follows, referring to
for extended batteries
and
for extended batteries:
a. Place the batteries in the drawer in the configuration shown.
b. Wire the batteries in series as shown.
c. Find the wiring harness coiled up on the floor of the battery back up drawer and plug
the Anderson connectors together as shown.
7. Move the gravity latch up, push the battery drawer in, and move the gravity latch down.
8. Reconnect the battery disconnect switch (DISC) on the LVD unit. For location, refer to
. The LVD LED on the low voltage disconnect unit should will turn
off when the batteries are reconnected.
Figure 35. Open Battery Drawer
21277-A
GRAVITY
LATCH
BATTERY
DRAWER