Single-Phase Electrical Lead Connections

Black

Positive

White or Red

Neutral

or L2

Green / Yellow

Ground

For 110V Single-Phase Applications

For 208-240V Single-Phase Applications

Single-Phase (1ø) Wiring Connections/Hookup

The electrical input connections on all single-phase (1ø) gas
dryers are made into the junction box located at the top left
rear area of the dryer (refer to 

page 7

).

For 208-240V Three-Phase Applications

A ground wire is provided in the electrical box to connect
your service ground.

Gas Information ______________________

It is your responsibility to have all plumbing connections made
by a qualified professional to ensure that the gas plumbing
installation is adequate and conforms to local and state
regulations or codes.  In the absence of such codes, all
plumbing connections, materials, and workmanship must
conform to the applicable requirements of the National Fuel
Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the
Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST
EDITION.
In Australia, the fuel gas code is AS 5601/AG 601, local
authority, gas, electricity, and any other relevant statutory
regulations.

Three-Phase Electrical Lead Connections

Black

L1

White

L2

Red

L3

Green / Yellow

Ground

IMPORTANT: 

Failure to comply with these codes or

ordinances, and/or the requirements stipulated in this
manual, can result in personal injury and improper
operation of the dryer.

Each dryer must have its own manual shutoff valve to provide
isolation of the dryer from the gas supply.
The dryer and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psig (3.5 kPa).  The dryer must be isolated from the gas
supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply system
at test pressures equal to or less than 1/2 psig (3.5 kPa).

IMPORTANT: 

Failure to isolate or disconnect the dryer

from supply as noted can cause irreparable damage to the
gas valve voiding the warranty.

!

 WARNING

Fire or explosion could result due to failure of
isolating or disconnecting gas supply as noted.

Gas Supply

The gas dryer installation must meet the American National
Standard...National Fuel Gas Code ANSI Z223.1-LATEST
EDITION, or in Canada, the Canadian Installation Codes
CAN/CGA-B149.1 M91 (Natural Gas) or CAN/CGA-B149.2-
M91 (L.P. Gas) or LATEST EDITION, as well as local codes
and ordinances and must be done by a qualified professional.

NOTE: 

Undersized gas piping will result in ignition

problems, slow drying, increased use of energy, and can
create a safety hazard.

The dryer must be connected to the type of heat/gas indicated
on the dryer data label.  If this information does not agree
with the type of gas available, do not operate the dryer.
Contact the reseller who sold the dryer or contact the
manufacturer.

IMPORTANT: 

Any burner changes or conversions must be

made by a qualified professional.

The input ratings shown on the dryer data label are for
elevations up to 2,000 feet (610 meters), unless elevation
requirements of over 2,000 feet (610 meters) were specified
at the time the dryer order was placed with the factory.  The
adjustment or conversion of dryers in the field for elevations
over 2,000 feet (610 meters) is made by changing each burner
orifice.  If this conversion is necessary, contact the reseller
who sold the dryer or contact the manufacturer.

IMPORTANT: 

This gas dryer is not provided with an

internal gas supply shutoff and an external gas supply
shutoff must be provided.

Summary of Contents for AD-444

Page 1: ...s supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres v...

Page 2: ...__________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or the ADC factory When ordering replacement parts from the factory you can FAX your order to ADC at 1 508 678 9447 or telephone your order directly to the ADC Parts Department at 1 508 678 9000 Please s...

Page 3: ...ld be supervised if near dryer s in operation Under no circumstances should the dryer door switch lint door switch or heat safety circuit ever be disabled Do not modify this appliance The dryer must never be operated with any of the back guards outer tops or service panels removed Personal injury or fire could result The dryer must never be operated without the lint filter screen in place even if ...

Page 4: ...rubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should be established for the inspection and cleaning of lint in the burner area exhaust ductwork and area around the back of the dryer The frequency of inspection and cleaning can best be determined from e...

Page 5: ...__________________________________________________________________________________ ___________________________________________________________________________________________________________________________________ ___________________________________________________________________________________________________________________________________ _____________________________________________________...

Page 6: ...10 Optional 2 20 32 cm 1 25 4 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 1 2 VOLTAGE AVAILABLE N A APPROXIMATE NET WEIGHT APPROXIMATE SHIPPING WEIGHT AIRFLOW PER POCKET EXHAUST CONNECTION DIAMETER PER POCKET COMPRESSED AIR CONNECTION COMPRESSED AIR VOLUME OVEN SIZE PER POCKET kW Btu hr kcal hr VOLTAGE AVAILABLE N A APPROXIMATE NET WEIGHT APPROXIMATE...

Page 7: ...dclaundry com 7 Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation ...

Page 8: ...ing will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber IMPORTANT The dryer must be installed in a location environment which the ambient temperature remains between 40 F 4 44 C and 130 F 54 44 C WARNING Excessive Weight Hazard Use two or more people and mechanical equipment to lift move and install dryer Failure to do so can result in...

Page 9: ...g should be level or below dryer cabinet for ease of removing panels during maintenance F Dryers may be positioned sidewall to sidewall however a 1 16 1 5875 mm minimum allowance must be made for the opening and closing of the control door along with the removal of panels during maintenance G 4 inch 10 16 cm maximum Fresh Air Supply Requirements ______ This appliance may only be installed in a roo...

Page 10: ...0 6 in WC 1 48 mb NOTE When the exhaust ductwork passes through a wall ceiling or roof made of combustible materials the opening must be 2 inches 5 08 cm larger than the duct all the way around The duct must be centered within this opening The ductwork for this dryer must be suitable for the appliance category in accordance with national installation regulations of the country of destination Outsi...

Page 11: ...t to the nearest obstruction The length of the ductwork from the dryer to the outside exhaust outlet must not exceed 20 feet 6 09 meters The minimum diameter of this ductwork must be at least 8 inches 20 32 cm when each pocket tumbler is vented individually and 10 inches 25 4 cm when both pockets tumblers are combined Including tumbler dryer elbow connections or elbows used for outside protection ...

Page 12: ...rounding must conform to applicable requirements of the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection may be to a proven earth ground at the location service panel For added personal safety when possible it is suggested that ...

Page 13: ...system at test pressures in excess of 1 2 psig 3 5 kPa The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply system at test pressures equal to or less than 1 2 psig 3 5 kPa IMPORTANT Failure to isolate or disconnect the dryer from supply as noted can cause irreparable damage to the gas valve voiding...

Page 14: ...as shutoff valve be provided to the gas supply line of each dryer for ease in servicing IMPORTANT When plumbing upper and lower tumblers together as illustrated below supply connection must be a minimum of 3 4 19 05 mm An 1 8 N P T plugged tap accessible for a test gauge connection must be installed in the main gas supply line immediately upstream of each dryer IMPORTANT Pipe joint compounds that ...

Page 15: ...ls and service box covers have been replaced Check the lint door to ensure that it is closed and secured in place Rotate the tumbler by hand to be sure it moves freely Preoperational Test __________________ All dryers are thoroughly tested and inspected before leaving the factory However a preoperational test should be performed before the dryer is publicly used It is possible that adjustments hav...

Page 16: ... open the main door Continuation of the cycle will resume only after the door has been closed and any of the three temperature selection buttons is pressed Upon completion of the drying and cooling cycles the tone buzzer will sound and the dryer will go into the Anti Wrinkle Mode if active for up to 99 minutes or until the main door or lint drawer has been opened IMPORTANT For more detailed inform...

Page 17: ...in writing either by FAX or CERTIFIED MAIL Return Receipt Requested as to the information necessary to process claim If reply is not received by the Warranty Department within 30 days from the FAX letter date then no replacements credits or refunds will be issued and the merchandise will be discarded Routine Maintenance ________________ Cleaning A program and or schedule should be established for ...

Page 18: ...rmostats Lubrication The motor bearings and under normal most conditions the tumbler bearings are permanently lubricated It is physically possible to relubricate the tumbler bearings if you choose to do so even though this practice is not necessary Use Shell Alvania 2 grease or its equivalent The tumbler bearings used in the dryer do not have a grease fitting Provisions are made in the bearing hou...

Page 19: ...____________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________...

Page 20: ...ADC Part No 112174 7 09 02 14 ...

Reviews: