ADC AD-30x2 Series Installation Manual Download Page 3

113019- 7

www.adclaundry.com

3

Safety Precautions .................................................. 4

Specifications .......................................................... 6

Installation Procedures ........................................... 7

Unpacking / Setting Up ................................................ 7
Location of the Dryer ................................................... 7
Dryer Enclosure Requirements ................................... 7
Fresh Air Supply Requirements .................................. 8
Exhaust Requirements ................................................ 8
Electrical Information ................................................. 10
Gas Information ......................................................... 11
Preparation for Operation / Start-Up ......................... 12
Preoperational Test ................................................... 13
Preoperational Instructions ....................................... 13
Shutdown Instructions ............................................... 13

Service / Parts Information ................................... 13

Service ...................................................................... 13
Parts .......................................................................... 13

Warranty Information ............................................. 14

Warranty Registration ............................................... 14
Warranty .................................................................... 14
Returning Warranty Parts .......................................... 14

Routine Maintenance ............................................ 14

Cleaning .................................................................... 14
Adjustments ............................................................... 15

Data Label Information .......................................... 15

Procedure for Functional Check
of Replacement Components ............................... 15

Non-Coin Programming ........................................ 16

Coin Programming ................................................ 17

Table of Contents _________________

Proposition 65

Use of   this product could expose you to

substances from fuel combustion that contain

chemicals known to the State of   California

to cause cancer, birth defects and other

reproductive harm.

In the State of Massachusetts, the following
installation instructions apply:

Installations and repairs must be performed by
a qualified or licensed contractor, plumber, or
gasfitter qualified or licensed by the State of
Massachusetts.

If using a ball valve, it shall be a T-handle type.

A flexible gas connector, when used, must not
exceed 3 feet.

List of Acronyms _________________________

D.M.S.

Drill Measurement Size

HVAC

Heating, Ventilating, and Air-Conditioning

in WC

Inches of Water Column

L.C.D.

Liquid Crystal Display

L.E.D.

Light Emitting Diode

L.P.

Liquid Propane

OSHA

Occupational Safety and Health Administration

R.M.A.

Return Material Authorization

UL

Underwriters Laboratory

!

 WARNING

IMPORTANT

You must disconnect and lockout the electric supply and

the gas supply or the steam supply before any covers or

guards are removed from the machine to allow access

for cleaning, adjusting, installation, or testing of any

equipment per OSHA standards.
Please observe all safety precautions displayed on the

equipment and/or specified in the installation manual

included with the dryer.

CAUTION

Dryer(s) should never be left unattended while in

operation.

“Caution: Label all wires prior to disconnection when

servicing controls.  Wiring errors can cause improper

operation.”

«Attention: Au moment de l’entretien des commandes,

étiquetez tous les fils avant de les débrancher.  Des

erreurs de câblage peuvent entraîner un fonctionnement

inadéquat et dangereux.»

WARNING

Children should not be allowed to play on or near the

dryer(s).  Children should be supervised if near dryer(s)

in operation.
Under no circumstances should the dryer door switch,

lint door switch, or heat safety circuit ever be disabled.
Do not modify this appliance.
The dryer must never be operated with any of the back

guards, outer tops, or service panels removed.  Personal

injury or fire could result.
The dryer must never be operated without the lint filter/

screen in place, even if an external lint collection system

is used.
If the hi-limit switch trips, a service call is required to

investigate the reason and resolve the issue.

FOR YOUR SAFETY

Do not dry mop heads in the dryer.  Do not use dryer

in the presence of dry cleaning fumes.

The dryers must not be installed or stored in an area

where it will be exposed to water and/or weather.
The wiring diagram for the dryer is located in the front

electrical control box area.

Summary of Contents for AD-30x2 Series

Page 1: ...s de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entreposer...

Page 2: ...___________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or...

Page 3: ...ration R M A Return Material Authorization UL Underwriters Laboratory WARNING IMPORTANT You must disconnect and lockout the electric supply and the gas supply or the steam supply before any covers or...

Page 4: ...ubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should...

Page 5: ...___________________________________________________________ ____________________________________________________________ NOTES _____________________________________________________ ___________________...

Page 6: ...UCK 36 42 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 520 lb 236 kg APPROXIMATE SHIPPING WEIGHT 550 lb 249 kg AIRFLOW PER POCKET 60 Hz 450 cfm 12 74 cmm 50 Hz 375 cfm 10 6 cmm HEAT...

Page 7: ...bustible floors only The dryer must not be installed or stored in an area where it will be exposed to water and or weather The dryer is for use in noncombustible locations The dryer must be installed...

Page 8: ...duct for each dryer The duct should go as directly as possible to the outside air Avoid sharp 90 right angle turns in ducting use 30 or 45 angles instead The radius of the elbows should preferably be...

Page 9: ...elbows Refer to the illustration below IMPORTANT The dryer exhaust duct must not be connected to any gas vent chimney wall ceiling or concealing space of a building It is recommended that exhaust or b...

Page 10: ...bligation Separate circuit for top and bottom pocket 8 18 14 Grounding A ground earth connection must be provided and installed in accordance with state and local codes In the absence of these codes g...

Page 11: ...ulator Incoming supply pressure must be consistent between a minimum of 6 0 in WC 14 92 mb and a maximum of 12 0 in WC 29 9 mb pressure Electrical Connections Leads Black Positive White Neutral Green...

Page 12: ...e should be determined by the gas supplier NOTE Undersized gas supply piping can create a low or inconsistent pressure which will result in erratic operation of the burner ignition system Preparation...

Page 13: ...of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating Preoperational Instructions __________ Coin Models Microprocessor Controller Computer When the micropr...

Page 14: ...burner area with a dusting brush or vacuum cleaner attachment Warranty Information ________________ Warranty Registration Visit us at www adclaundry com and register all of your new dryers by clickin...

Page 15: ...a red L E D diagnostic indicator will flash An unlit red L E D diagnostic indicator indicates normal operation A lit green L E D diagnostic indicator indicates dryer controller is calling for heat an...

Page 16: ...ILSWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT F...

Page 17: ...closed before starting SAIL SWITCH OPEN Sail switch failed to close after starting BURNER HI LIMIT Oven thermostat switch has opened EXHAUST HI LIMIT Tumbler thermostat switch has opened BURNER CONTRO...

Page 18: ...ADC Part No 113019 7 08 20 14...