MAXIMUM CAPACITY (DRY WEIGHT)  

PER POCKET

30 lb

13.6 kg

TUMBLER DIAMETER

30”

76.2 cm

TUMBLER DEPTH

27”

68.5 cm

TUMBLER VOLUME  

PER POCKET

11 cu ft

 311.5 L

TUMBLER / DRIVE MOTOR  

PER POCKET

1/4 hp

0.19 kW

BLOWER / FAN MOTOR  

PER POCKET

1/2 hp

0.37 kW

DOOR OPENING (DIAMETER)

21-1/2”

54.6 cm

DOOR SILL HEIGHT  

                         TOP POCKET / BOTTOM POCKET

51-3/4” / 13-1/8”

131.4 cm / 33.3 cm

DRYERS PER 20’ / 40’ CONTAINER

14 / 28

DRYERS PER 48’ / 53’ TRUCK

36 / 42

VOLTAGE AVAILABLE

120-240V    1ø    2w    50/60 Hz

APPROXIMATE NET WEIGHT

520 lb

236 kg

APPROXIMATE SHIPPING WEIGHT

550 lb

249 kg

AIRFLOW  

PER POCKET

60 Hz

450 cfm

12.74 cmm

50 Hz

375 cfm

10.6 cmm

HEAT INPUT

 

 

PER POCKET

72,000 Btu/hr

18,144 kcal/hr

EXHAUST CONNECTION (DIAMETER)  

PER DRYER

8”

20.3 cm

INLET PIPE CONNECTION  

PER DRYER

1/2” M.N.P.T.

1/2” B.S.P.T.  

(CE and Australia Only)

Specifications _____________________________________________________________________

NOTE:

 The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

GAS

Shaded areas are stated in metric equivalents

4/10/14

Summary of Contents for AD-30x2 Series

Page 1: ...s de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entreposer...

Page 2: ...___________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or...

Page 3: ...ration R M A Return Material Authorization UL Underwriters Laboratory WARNING IMPORTANT You must disconnect and lockout the electric supply and the gas supply or the steam supply before any covers or...

Page 4: ...ubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should...

Page 5: ...___________________________________________________________ ____________________________________________________________ NOTES _____________________________________________________ ___________________...

Page 6: ...UCK 36 42 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 520 lb 236 kg APPROXIMATE SHIPPING WEIGHT 550 lb 249 kg AIRFLOW PER POCKET 60 Hz 450 cfm 12 74 cmm 50 Hz 375 cfm 10 6 cmm HEAT...

Page 7: ...bustible floors only The dryer must not be installed or stored in an area where it will be exposed to water and or weather The dryer is for use in noncombustible locations The dryer must be installed...

Page 8: ...duct for each dryer The duct should go as directly as possible to the outside air Avoid sharp 90 right angle turns in ducting use 30 or 45 angles instead The radius of the elbows should preferably be...

Page 9: ...elbows Refer to the illustration below IMPORTANT The dryer exhaust duct must not be connected to any gas vent chimney wall ceiling or concealing space of a building It is recommended that exhaust or b...

Page 10: ...bligation Separate circuit for top and bottom pocket 8 18 14 Grounding A ground earth connection must be provided and installed in accordance with state and local codes In the absence of these codes g...

Page 11: ...ulator Incoming supply pressure must be consistent between a minimum of 6 0 in WC 14 92 mb and a maximum of 12 0 in WC 29 9 mb pressure Electrical Connections Leads Black Positive White Neutral Green...

Page 12: ...e should be determined by the gas supplier NOTE Undersized gas supply piping can create a low or inconsistent pressure which will result in erratic operation of the burner ignition system Preparation...

Page 13: ...of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating Preoperational Instructions __________ Coin Models Microprocessor Controller Computer When the micropr...

Page 14: ...burner area with a dusting brush or vacuum cleaner attachment Warranty Information ________________ Warranty Registration Visit us at www adclaundry com and register all of your new dryers by clickin...

Page 15: ...a red L E D diagnostic indicator will flash An unlit red L E D diagnostic indicator indicates normal operation A lit green L E D diagnostic indicator indicates dryer controller is calling for heat an...

Page 16: ...ILSWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT F...

Page 17: ...closed before starting SAIL SWITCH OPEN Sail switch failed to close after starting BURNER HI LIMIT Oven thermostat switch has opened EXHAUST HI LIMIT Tumbler thermostat switch has opened BURNER CONTRO...

Page 18: ...ADC Part No 113019 7 08 20 14...