Preoperational Test __________________

All dryers are thoroughly tested and inspected before leaving
the factory.  However, a preoperational test should be
performed before the dryer is publicly used.  It is possible that
adjustments have changed in transit or due to marginal location
(installation) conditions.  Installer must instruct the user on
how to correctly operate the dryer before leaving.
Turn on electric power to the dryer.
Refer to the operating instructions for starting your particular
model dryer.

Gas Dryers

When a gas dryer is first started (during initial start-up), it has
a tendency not to ignite on the first ignition attempt.  This is
because the gas supply piping is filled with air, so it may take
a few minutes for the air to be purged from the lines.

NOTE: 

During the purging period, check to be sure that all

gas shutoff valves are open.
Gas model dryers are equipped with an ignition system,
which has internal diagnostics.  If ignition is not established
after one time, the heat circuit in the ignition module will
attempt two more ignitions (total of three ignition attempts).
If there is no flame after the third ignition attempt, the
module will lock out until it is manually reset.  To reset the
ignition system, open and close the main door and restart
the dryer.

A burner gas pressure measurement should be taken at the
gas valve outlet pressure tap of each gas valve to ensure that
the water column pressure is correct and consistent.

NOTE: 

Water column burner pressure requirements

(measured at the outlet pressure tap of the gas valve body):
Natural Gas ........ 3.5 in WC (8.7 mb).
L.P. Gas .............. 10.5 in WC (26.1 mb).

IMPORTANT: 

There is no regulator provided in an L.P.

dryer.  The water column pressure must be regulated at the
source (L.P. tank) or an external regulator must be added to
each dryer.

Make a complete operational check of all safety related circuits:
Door Switch(es)
Hi-Limit Thermostats
Cycling Thermostats
Sail Switch
Make a complete operational check of all operating controls.

NOTE: 

If computer program changes are required, refer to

the computer programming section of the manual supplied
with the dryer.

The dryer should be operated through one complete cycle to
ensure that no further adjustments are necessary and that all
components are functioning properly.

Tumbler Coating

The tumbler is treated with a protective coating.  We suggest
dampening old garments or cloth material with a solution of
water and nonflammable mild detergent and tumbling them in
the tumbler to remove this coating.

Preoperational Instructions __________

Coin Models
Microprocessor Controller (Computer)

When the microprocessor controller (computer) is in the ready
state, the L.C.D. screen will display “FILL” followed by the
amount to start.
Insert coin(s).  Once the correct “Amount to Start” has been
inserted, the L.C.D. will display “PUSH”.
Select temperature by pressing “HI,” “LO,” or “PERM PRESS.”
The cycle will start and the L.C.D. will display the Dry Cycle
selected and the remaining time.
The dryer will continue through the drying and cooling cycles,
until the vended time has expired.

NOTE:

 To stop the dryer, open the main door.  Continuation

of the cycle will resume only after the door has been closed
and any of the three temperature selection buttons is
pressed.

Upon completion of the drying and cooling cycles, the tone
(buzzer) will sound and the dryer will go into the Anti-Wrinkle
Mode, if active, for up to 99 minutes, or until the main door or
lint drawer has been opened.

IMPORTANT: 

For more detailed information regarding the

microprocessor controller (computer) on your dryer, refer to
the microprocessor user’s manual included with the dryer.

Shutdown Instructions _______________

If the dryer is to be shutdown (taken out of service) for a period
of time, the following must be performed:
Discontinue power to the dryer either at the external disconnect
switch or the circuit breaker.
Discontinue the gas supply (for gas models only):
Shut off external gas supply shutoff valve.

Service / Parts Information __________

Service

Service must be performed by a qualified trained technician,
service agency, or gas supplier.  If service is required, contact
the reseller from whom the equipment was purchased.  If the
reseller cannot be contacted or is unknown, contact the Service
Department for a reseller in your area.

NOTE: 

When contacting the Service Department, be sure to

give them the correct model number and serial number so
that your inquiry is handled in an expeditious manner.

Parts

Replacement parts should be purchased from the reseller from
whom the equipment was purchased.  If the reseller cannot
be contacted or is unknown, contact the Parts Department for
a reseller in your area.  Parts may also be purchased directly
from the factory by calling the Parts Department at (508)
678-9000, FAX in your order at (508) 678-9447, or visit us
online at www.adclaundry.com.

NOTE: 

When ordering replacement parts from the reseller

or the manufacturer, be sure to give them the correct model
number and serial number so that your parts order can be
processed in an expeditious manner.

Summary of Contents for AD-30x2 Series

Page 1: ...s de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entreposer...

Page 2: ...___________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or...

Page 3: ...ration R M A Return Material Authorization UL Underwriters Laboratory WARNING IMPORTANT You must disconnect and lockout the electric supply and the gas supply or the steam supply before any covers or...

Page 4: ...ubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should...

Page 5: ...___________________________________________________________ ____________________________________________________________ NOTES _____________________________________________________ ___________________...

Page 6: ...UCK 36 42 VOLTAGE AVAILABLE 120 240V 1 2w 50 60 Hz APPROXIMATE NET WEIGHT 520 lb 236 kg APPROXIMATE SHIPPING WEIGHT 550 lb 249 kg AIRFLOW PER POCKET 60 Hz 450 cfm 12 74 cmm 50 Hz 375 cfm 10 6 cmm HEAT...

Page 7: ...bustible floors only The dryer must not be installed or stored in an area where it will be exposed to water and or weather The dryer is for use in noncombustible locations The dryer must be installed...

Page 8: ...duct for each dryer The duct should go as directly as possible to the outside air Avoid sharp 90 right angle turns in ducting use 30 or 45 angles instead The radius of the elbows should preferably be...

Page 9: ...elbows Refer to the illustration below IMPORTANT The dryer exhaust duct must not be connected to any gas vent chimney wall ceiling or concealing space of a building It is recommended that exhaust or b...

Page 10: ...bligation Separate circuit for top and bottom pocket 8 18 14 Grounding A ground earth connection must be provided and installed in accordance with state and local codes In the absence of these codes g...

Page 11: ...ulator Incoming supply pressure must be consistent between a minimum of 6 0 in WC 14 92 mb and a maximum of 12 0 in WC 29 9 mb pressure Electrical Connections Leads Black Positive White Neutral Green...

Page 12: ...e should be determined by the gas supplier NOTE Undersized gas supply piping can create a low or inconsistent pressure which will result in erratic operation of the burner ignition system Preparation...

Page 13: ...of water and nonflammable mild detergent and tumbling them in the tumbler to remove this coating Preoperational Instructions __________ Coin Models Microprocessor Controller Computer When the micropr...

Page 14: ...burner area with a dusting brush or vacuum cleaner attachment Warranty Information ________________ Warranty Registration Visit us at www adclaundry com and register all of your new dryers by clickin...

Page 15: ...a red L E D diagnostic indicator will flash An unlit red L E D diagnostic indicator indicates normal operation A lit green L E D diagnostic indicator indicates dryer controller is calling for heat an...

Page 16: ...ILSWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT F...

Page 17: ...closed before starting SAIL SWITCH OPEN Sail switch failed to close after starting BURNER HI LIMIT Oven thermostat switch has opened EXHAUST HI LIMIT Tumbler thermostat switch has opened BURNER CONTRO...

Page 18: ...ADC Part No 113019 7 08 20 14...