Troubleshooting
150-432-100-02, Revision 02
42
July 18, 2002
HLU-432 List 1
Table 13.
Summary of HiGain Loopback Codes
Method of Transmission
Loopback
Code
Description
Test Set
Craft Port
MODE/SEL
NLOC
1111000
4-in-7
Network Local. Invokes HLU loopback toward the network.
X
X
X
NDU1
110000
2-in-6
Network Doubler 1. Invokes HDU1 loopback toward the
network.
X
X
X
NDU2
111000
3-in-6
Network Doubler 2. Invokes HDU2 loopback toward the
network.
X
X
X
NDU3
1010001
Network Doubler 3. Invokes HDU3 loopback toward the
network.
X
X
X
NDU4
1010010
Network Doubler 4. Invokes HDU4 loopback toward the
network.
X
X
X
NREM
1110000
3-in-7
Network Remote. Invokes HRU loopback towards the
network.
X
X
X
CLOC
1111100
5-in-7
Customer Local. Invokes HRU loopback towards the
customer.
X
X
X
CDU1
111100
4-in-6
Customer Doubler 1. Invokes HDU1 loopback towards the
customer.
X
X
X
CDU2
111110
5-in-6
Customer Doubler 2. Invokes HDU2 loopback towards the
customer.
X
X
X
CDU3
1011001
Customer Doubler 3. Invokes HDU3 loopback towards the
customer.
X
X
X
CDU4
1011010
Customer Doubler 4. Invokes HDU4 loopback towards the
customer.
X
X
X
CREM
1111110
6-in-7
Customer Remote. Invokes HLU loopback towards the
customer.
X
X
X
SMJK LpUp
(PL)
11000
2-in-5
SmartJack Loopup or NID payload (PL) code. Invokes
HRU loopback towards network.
X
SMJK LpUp
(ESF-DL)
1111-1111-
0100-1000
SmartJack Loopup or NID (ESF-DL) code. Invokes HRU
loopback towards network.
X
SMJK LpDn
(PL)
11100
3-in-5
SmartJack Loopdown or NID payload (PL) code. Removes
SMJK, NLOC, NREM, CREM, CLOC, CDUn, and NDUn.
X
SMJK LpDn
(ESF-DL)
1111-1111-
0010-0100
SmartJack Loopdown or NID (ESF-DL) code. Removes
SMJK, NLOC, NREM, CREM, CLOC, CDUn, and NDUn.
X
HiGain systems feature the SmartJack option, which can emulate a Network Interface Device
(NID) for the purpose of loopback testing of the HiGain circuit. SMJK and NREM loopbacks
perform the same functions but their initiation differs. SMJK indicates that the loopback was
initiated by the 2-in-5 inband command. NREM, on the other hand, is initiated by the 3-in-7
inband command or by a command issued from the maintenance terminal or the MODE and SEL
buttons.
Use the inband commands to enable or disable the SMJK loopback options. The HLU-432
system setting is normally enabled to recognize all inband SmartJack loopback commands.