EURODIM TWIN TECH
Page
90
sur
92
9.1
P
ROCEDURE TO BE FOLLOWED IN THE
E
VENT OF AN
E
RROR
Errors list
Action
Downgraded mode
r, s, t phase error
−
Verify the external network
−
Verify the connections on the
cabinet
−
Verify the main breaker in the
cabinet
−
Verify the CTRL fuses
The modules connected on
the faulty phase are no
longer useable.
Fan 1, 2, 3 error
−
Proceed with replacing the
cabinet’s faulty fa
n
Risk of an increase in the
temperature inside the
cabinet. See temperature
error.
Controller error
−
Switch the cabinet off/on at the
mains to remove the error,
where applicable
−
Switch to the controller (if
present) using the cabinet
selector
−
Stop the cabinet and proceed
with replacing the controller
Communication error
−
Verify the connections between
the TTD HUMAN INTERFACE
(HMI) and the cabinet
TTD HUMAN INTERFACE
(HMI) will no longer be
synchronised with this
controller
24 V, 9 V, 9 V control and
1V2 error
−
Switch to the controller (if
present) using the cabinet
selector
−
Stop the cabinet and proceed
with replacing the controller
Temperature error
−
Refresh the room temperature
(See chapter cabinet fan)
Automatic reduction of the
circuit control value until
the temperature is
acceptable