Appendix C: Using the Adaptec RAID Controller Utility
●
98
SCSI-specific Controller Settings
In addition to the general settings listed on
, your Adaptec SCSI
controller has SCSI-specific settings that can be modified if required.
To modify SCSI-specific settings, select
SCSI Configuration
from the
SCSISelect main menu.
SCSI Channel Interface Settings
Note:
Default settings are shown in
bold
type.
SCSI Device Settings
You can use SCSISelect to modify some of the settings on the SCSI
devices connected to your SCSI controller.
To modify SCSI device settings, select
SCSI Configuration
from the
SCSISelect main menu, then select
Additional Options
. Devices are
listed by SCSI ID. (To find the SCSI ID for a specific device, see
Formatting and Verifying Disk Drives on page 99
Option
Description
Controller SCSI
Channel ID
Sets the controller’s SCSI ID. Adaptec recommends that
you leave the controller set to the default (
7
), which gives
it the highest priority on the SCSI channel.
SCSI Parity
Checking
When enabled, the controller verifies the accuracy of data
transfer on the SCSI channel. Disable only if the
controller is connected to any SCSI device that does not
support SCSI parity. Default is
enabled
.
Controller SCSI
Channel
Termination
Sets termination on the controller. Adaptec recommends
that you retain the default setting (
auto mode
).