background image

February 2012 

80-0180-327 Rev. F 

O

PERATIONAL

 D

ESCRIPTION

 

Manual Operation – Key Cylinder 
1.  Insert key into lock cylinder. 
2.  Turn the key 180° to the detent position and hold. 
3.  Rotate the lever until latch or deadbolt clear the strike and open the door. 
4.  Return the key to the 12 o’clock position and remove the key. 

Credential Card Operation 

When the eForce

®

 is in a secured state, the LED in the front plastic faceplate 

will be red, and the lever will not operate the locking mechanism.  

To gain entry using the eForce

®

 Prox or eForce

®

 iCLASS: 

Place Prox/iCLASS card in front of the eForce

®

 LED, at a 

distance no 

greater than one inch

.  

The access control system will receive the card credential information, 
and will send an unlock signal to the eForce

® 

if the credentials are valid. 

The LED will change states from red to green, and a short audible tone 
will be heard to indicate a valid unlock status. 
Rotate the lever to gain entry into the building. 
The lock will return to a secured (locked state) (

does not apply to  

deadbolt

) after the access control system unlock period has expired.  

NOTE: the access control system will determine the unlock period. There 
are no adjustments in the eForce

®

 for unlock period. 

Adding Card Credentials 
Consult the access control system manual or the system administrator to 
manage your credential database.  The eForce

®

 does not store card creden-

tials; it simply extracts the information from the card and sends it to the ac-
cess control system for verification. 

80-0180-327 Rev. F 

15 

February 2012 

STEP 5     MORTISE CYLINDER INSTALLATION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                       F

IG

. 14

 

 

 

Using a Philips Head Screwdriver, 
remove the eight (8) #10-32 x 5/8” 
screws on the back of the eForce

®

 

and gently lift the back plate off the 
housing.

 

 

 

C

AUTION

!

 There are wires connecting 

the housing and back plate assembly. 
Handle with care.

 

 

Do not over-tighten!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                       F

IG

. 15

 

 

 

Install Cylinder into housing. Secure 
and fasten with supplied locking ring 
using locking ring spanner tool.   
(F

IG

. 14)

 

 

 

Gently place back plate back on 
housing and secure with eight (8) 
#10-32 x 5/8” screws. 

 

 

C

AUTION

!

 There are wires connecting 

the housing and back plate assembly. 
Handle with care.

 

 

Do not over-tighten!

 

 

Do not use Dummy Cylinder!

 

Summary of Contents for eForce 3090C

Page 1: ...na CA 91767 Phone 800 872 3267 Fax 800 232 7329 www adamsrite com eForce Keyless Entry Adams Rite Manufacturing Co 260 Santa Fe Street Pomona CA 91767 Phone 800 872 3267 www adamsrite com Owner s Manu...

Page 2: ...usions This is a limited warranty and is in lieu of all other warranties including the implied warranties of merchantability and fitness for use and under no circumstances shall ADAMS RITE be liable f...

Page 3: ...ions 4 FCC Statement 5 IC Statement 5 Operational Description 6 Operational Specifications 7 Troubleshooting 8 Installation Tools Equipment 9 Door Preparation 10 Spindle Preparation 11 Lock Series Con...

Page 4: ...Prox Class of contactless card credentials that operate on 125kHz iCLASS Class of contactless card credentials that operate on 13 56MHz Note iCLASS fundamental frequency allows use of card credentials...

Page 5: ...ipment does cause harmful interference to radio or tele vision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or...

Page 6: ...locked state does not apply to deadbolt after the access control system unlock period has expired NOTE the access control system will determine the unlock period There are no adjustments in the eForce...

Page 7: ...ll iCLASS 13 56MHz credentials Electrical Specifications Prox iCLASS Power Requirements Voltage In 12Vdc Range 10 8Vdc 16Vdc Current Consumption 150mA average 300mA peak Transmit Frequencies Prox 125k...

Page 8: ...e Wiegand lines are connected properly Place card in front of eForce If the eForce emits one short tone but lock does not activate check Wiegand data lines for connectivity and proper connec tion 80 0...

Page 9: ...evices Corbin Russwin ED4000 Series and SARGENT 8500 Narrow Design Rim Exit Devices The 3090P 02 3090C 02 are compatible with Adams Rite MS Series Deadbolts only THESE UNITS ARE NOT INTERCHANGEABLE Th...

Page 10: ...y 2012 STEP 2 SPINDLE PREPARATION For 1 3 4 doors For Adams Rite MS1850 Deadbolts 4500 4900 Deadlatches 8000 Series Mortise Exit Devices Snap off spindle at fifth 5th notch as shown in FIG 4 For 2 thi...