February 2012
6
80-0180-327 Rev. F
O
PERATIONAL
D
ESCRIPTION
Manual Operation – Key Cylinder
1. Insert key into lock cylinder.
2. Turn the key 180° to the detent position and hold.
3. Rotate the lever until latch or deadbolt clear the strike and open the door.
4. Return the key to the 12 o’clock position and remove the key.
Credential Card Operation
When the eForce
®
is in a secured state, the LED in the front plastic faceplate
will be red, and the lever will not operate the locking mechanism.
To gain entry using the eForce
®
Prox or eForce
®
iCLASS:
Place Prox/iCLASS card in front of the eForce
®
LED, at a
distance no
greater than one inch
.
The access control system will receive the card credential information,
and will send an unlock signal to the eForce
®
if the credentials are valid.
The LED will change states from red to green, and a short audible tone
will be heard to indicate a valid unlock status.
Rotate the lever to gain entry into the building.
The lock will return to a secured (locked state) (
does not apply to
deadbolt
) after the access control system unlock period has expired.
NOTE: the access control system will determine the unlock period. There
are no adjustments in the eForce
®
for unlock period.
Adding Card Credentials
Consult the access control system manual or the system administrator to
manage your credential database. The eForce
®
does not store card creden-
tials; it simply extracts the information from the card and sends it to the ac-
cess control system for verification.
80-0180-327 Rev. F
15
February 2012
STEP 5 MORTISE CYLINDER INSTALLATION
F
IG
. 14
Using a Philips Head Screwdriver,
remove the eight (8) #10-32 x 5/8”
screws on the back of the eForce
®
and gently lift the back plate off the
housing.
C
AUTION
!
There are wires connecting
the housing and back plate assembly.
Handle with care.
Do not over-tighten!
F
IG
. 15
Install Cylinder into housing. Secure
and fasten with supplied locking ring
using locking ring spanner tool.
(F
IG
. 14)
Gently place back plate back on
housing and secure with eight (8)
#10-32 x 5/8” screws.
C
AUTION
!
There are wires connecting
the housing and back plate assembly.
Handle with care.
Do not over-tighten!
Do not use Dummy Cylinder!