background image

 

13.1.1 

AUTO POWER OFF 

 

  The first parameter is to set the auto power off function. The 

display will show “

Pr oFF

” (DEFAULT SET). 

 

 Press 

[Tare/Zero]

 to toggle between “

Pr

 

on

” and “

Pr

 

oFF

”. 

 

 

Enables the Auto Power Off function. 
The power will be turned off after 2 
minutes if a key has not been 
pressed for 2 minutes and the scale 
is at zero. If there is any weight on 
the scale or a key is pressed, the 
scale will continue to work. 

 

Disables the Auto Power Off function. 
The scale will not automatically turn 
off. 

 

 

 

 

 

 Press 

the 

[Unit]

 key to confirm the selection and move to the 

next parameter. 

 

 

 

13.1.2 

SETTING OF BACKLIGHT 

 

  The second parameter to set the backlight function. Display 

will show “

bL  3

” (DEFAULT SET). 

 

 Press 

the 

[Tare/Zero]

 key to change the settings  

 

Off- backlight is switched off always 

 

 

On- backlight is set to on always 

 

 

Automatic- backlight will be off unless a 
weight is placed on the pan.  When the 
weight is removed it will stay on for 10 
seconds after the scale returns to zero. 

 

 

 Press 

the 

[Unit]

 key to confirm the selection and move to the 

next parameter. 

 

 

© Adam Equipment Company 2008 

 

17

Summary of Contents for CPWplus 150

Page 1: ...Adam Equipment CPWplus RANGE OF SCALES P N 9009 Rev B May 2008 Adam Equipment Company 2008...

Page 2: ...Adam Equipment Company 2008...

Page 3: ...INTERFACE 13 12 0 CALIBRATION 15 13 0 PARAMETER SETTING 16 13 1 USER PARAMETERS 16 13 1 1 AUTO POWER OFF 17 13 1 2 SETTING OF BACKLIGHT 17 13 1 3 ENABLING OF UNITS 18 13 1 4 COMMUNICATION ADDRESS 18...

Page 4: ...Adam Equipment Company 2008 2...

Page 5: ...istant keyboard has 4 easy to use function keys On Off Print Hold Unit and Tare Zero All scales are supplied with the Power Supply module Adam Equipment Company 2008 3 300 x 300mm base operates with 6...

Page 6: ...10 kg 0 2 lb 0 10 kg 0 2 lb 0 2 kg 0 4 lb Series CPWplus CPWplus M CPWplus L Platform size 300 x 300 mm 9 500 x 500 mm 9 900 x 600 mm 9 Power Option 12 VAC 150 mA Power supply module supplied 9 9 9 6...

Page 7: ...latform 9 Stainless Steel Pan 9 Power supply Module 9 An Instruction manual CPWplus M 9 CPWplus Indicator with bracket and 2 screws 9 The Platform 9 Stainless Steel Pan 9 Power supply Module 9 An Inst...

Page 8: ...on Avoid unstable power sources Do not use the scale near large users of electricity such as welding equipment or large motors Do not place the scale near vibrating machinery Avoid high humidity that...

Page 9: ...ow The alkaline batteries are suggested for use for best life Adam Equipment Company 2008 7 NOTE When moving the scale take care to prevent bending of the cable and connector too much as over a period...

Page 10: ...e of the indicator use the two thumb screws on the side of the bracket that connects the indicator The Indicator can be placed on any flat surface or mounted on the wall Connect the cable attached to...

Page 11: ...r net zero by storing Tare Zero the current weight in the tare memory 5 0 DISPLAY 6 0 SYMBOLS AND INDICATORS Symbol Description Scale is in the zero position 0 Weighing result is stable Active weighin...

Page 12: ...odule to the rear of the indicator and apply power The scale need not be turned on The battery should be charged for 12 hours for full capacity The battery life is approximately 60 hours 8 0 BACKLIGHT...

Page 13: ...nnect the power supply module to the rear of the indicator and switch on the mains 10 2 ZEROING The ZERO and TARE function is combined into one key Tare Zero You can press the Tare Zero key at any tim...

Page 14: ...be tared a second time if another type of product was to be added to the first one Again only the weight of the product that is added after taring will be displayed When the container is removed a ne...

Page 15: ...as described in 10 3 The scale then shows the net weight of the material added 11 0 RS 232 INTERFACE The CPWplus scales come with a bi directional RS 232 interface Interface parameters are RS 232 outp...

Page 16: ...n below Input commands format Z cr lf Tares the scale to display the net weight same as pressing Tare Zero H cr lf Sets the scale to hold if the hold function is enabled Same as pressing the Hold key...

Page 17: ...cted unit The unit can be changed by using the Unit key to calibrate in kg or lb Press the Print Hold key The display will show L xx where xx is the Calibration weight which is user selectable Use the...

Page 18: ...correctly Repeat the process if necessary 13 0 PARAMETER SETTING 13 1 USER PARAMETERS The scale can be set as desired by the user to control the weighing operation See section 18 0 for the complete li...

Page 19: ...wer Off function The scale will not automatically turn off Press the Unit key to confirm the selection and move to the next parameter 13 1 2 SETTING OF BACKLIGHT The second parameter to set the backli...

Page 20: ...are set press the Unit key to move to the next parameter 13 1 4 COMMUNICATION ADDRESS The fourth parameter is for setting the ID for the RS 232 results output Display will show Add 0 DEFAULT SET This...

Page 21: ...ss the Unit key to confirm the selection and move to the next parameter 13 1 6 SELECTION OF BIT RATE AND PARITY The sixth parameter is to select the bit rate and parity used for sending data to RS 232...

Page 22: ...to confirm the selection and move to the next parameter 13 1 8 SELECTION OF HOLD FUNCTION The eighth parameter is to set the Hold function Display will show Hod 1 DEFAULT SET See the HOLD AND PRINTIN...

Page 23: ...It is applicable if the hold function is set to Hod 2 or Hod 3 Use the Tare Zero key to scroll through the options The options are Holds the display for an infinite time limit Holds the display for 15...

Page 24: ...ressed Hold is released if Print Hold is pressed again or time expires as per Hti setting Print continuously Hold occurs when the Print Hold key is pressed Hold is released if Print Hold is pressed ag...

Page 25: ...t parameter 13 2 2 ZERO TRACKING This parameter is for setting the range of the zero tracking Zero tracking will aid the scale to hold or return to zero and should be increased if large weights are le...

Page 26: ...the highest When the desired value is displayed press the Print Hold key to select the value and exit the Technical Parameters The display will count down to zero and the scale will return to normal w...

Page 27: ...that caused the message such as turning the scale on calibration or any other functions If the error message is still shown contact your supplier for further support 15 0 REPLACEMENT PARTS AND ACCESSO...

Page 28: ...ased This part of information should always be available for any future correspondence We suggest you to fill in this form as soon as the unit is received and keep a print out in your record for ready...

Page 29: ...he equipment is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover e...

Page 30: ...18 0 APPENDIX Adam Equipment Company 2008 28...

Page 31: ...a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with th...

Page 32: ...edical Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of...

Reviews: