25 |
P a g e
© Adam Equipment Company 2017
It is then necessary to enter this value (rounded to 3 places:
x.xxx) into memory as above. For example 12883g for 2000
tokens is an average of 6.4415 grams, Enter 6.442 grams.
5.3 SECURED
FEATURES
The CCEU Coin Counting scale has a number of functions that can only be
accessed by a qualified user.
Two levels of security are available. For the first level of security, a user
password is required to allow the access to change the piece weight for the
different denominations of coins. See Section 5.1.
The second level of security will allow more functions to be set. See section
6.0.
The first level of functions includes:
F1
Baud Rate
F2
Parity
F3
Sleep
F4
Calibration
F5
Access Code Number Setting
F6 Language