background image

 

13.0 REPLACEMENT PARTS AND ACCESSORIES 

 

If you need to order any spare parts and accessories, contact your supplier or Adam 
Equipment. A partial list of such items is as follows- 

 

 

Power Supply Module 

 

Main Power cord 

 

Replacement Battery 

 

Stainless Steel Pan 

 

 

Range of Platforms 

 

In use cover 

 

Printer, etc. 

 

 

 
 

14.0 SERVICE INFORMATION 

 

This manual covers the details of operation. If you have a problem with the 
scale that is not directly addressed by this manual then contact your supplier for 
assistance. In order to provide further assistance, the supplier will need the 
following information which should be kept ready: 

 

 

A.

 

Details of your company

    -Name of your company: 
    -Contact person’s name: 
    -Contact telephone, e-mail,  
     fax or any other methods: 
 

B.

 

Details of the unit purchased

  

     

(This part of information should always be available for any future 

correspondence. We suggest you to fill in this form as soon as the unit is 
received and keep a print-out in your record for ready reference.) 

            

Model name of the scale: 
 

CBDa_______ 

Serial number of the unit: 
 

 

Software revision number  
(Displayed when power is first turned on): 

 

Date of Purchase: 

 

Name of the supplier and place: 

 

         
  

 

  © Adam Equipment Company 2005 

 

32

Summary of Contents for CBD 100a

Page 1: ...Adam Equipment CBDa SERIES P N 6242 Revision A7 September 2005 Software revision 1 4 1 11 Adam Equipment Company 2005...

Page 2: ...omatic accumulated total 14 6 3 PARTS COUNTING 15 6 3 1 Weighing a sample to determine the Unit Weight 15 6 3 2 Entering a known Unit Weight 16 6 3 3 Automatic update of unit weight 16 6 3 4 Count pre...

Page 3: ...ween pounds and kilograms All have stainless steel weighing platform on a Steel base assembly All the keypads are sealed colour coded membrane switches and the displays are large easy to read liquid c...

Page 4: ...2 g 0 001 lb 0 5 g 0 002 lb 1 g 0 005 lb 2 g Linearity 0 0004 lb 0 2 g 0 001 lb 0 4 g 0 002 lb 1 g 0 004 lb 2 g 0 01 lb 4 g Units of Measure Lb g lb kg 2 2 SPECIFICATIONS FOR THE REMOTE SCALE Excitati...

Page 5: ...Housing Indicator ABS Plastic Stainless Steel platform Pan size 8 9 x 10 8 225 x 275 mm Overall dimensions 12 4 x 14 x 4 3 315 x 355 x 110 mm Net weight 9 lb 4 1 kg Applications Counting Scale Functio...

Page 6: ...ng machinery Avoid high humidity that might cause condensation Avoid direct contact with water Do not spray or immerse the scales in water Avoid air movement such as from fans or opening doors Do not...

Page 7: ...1 The first number 1 4 is the hardware revision number of the main circuit board and the next one 1 11 is the software revision number Next a self test is followed At the end of the self test it will...

Page 8: ...scale can be set to a high resolution with a maximum of 1 30 000 i e 300kg x 10g It will also be possible to sample on the remote scale with the same accuracy as the Local Where more than one load cel...

Page 9: ...e Up to 99 values or full capacity of the weight display can be added Also prints the displayed values when Auto print is switched off Smpl This is used to enter the number of items of a sample PLU To...

Page 10: ...the current weight in the memory as a tare value subtracting the tare value from the total weight and displaying the results as a net weight 5 0 DISPLAYS The scales have three display windows Weight U...

Page 11: ...e user of a potential problem 5 3 COUNT WINDOW This display will show the number of items on the scale or the value of the accumulated count See the OPERATION section An arrow above the symbols will i...

Page 12: ...local to remote a clear display will be shown to identify the change and the scales will count based on the tare and unit weight currently in use for the scale selected Display for the change is c h...

Page 13: ...s applicable by pressing the Local Rem key Preset tare values can be used with both the local and remote scale If a new tare value is to be used there are two methods for entering a tare value The fir...

Page 14: ...cimal point using the keypad press Tare Zero to store the tare value The weight will show a negative value equal to the tare Place the container on the platform The display will then show the weight o...

Page 15: ...to the memory More products can then be added and the M key pressed again This can continue for up to 99 entries or until the capacity of the Weight display is exceeded To observe the total value stor...

Page 16: ...ill give greater accuracy when counting larger sample sizes 6 3 1 Weighing a sample to determine the Unit Weight To determine the average weight of the items to be counted place a known quantity of th...

Page 17: ...section After the scale is tared the items to be counted are added and the Count display will show the number of items computed using the weight and the unit weight It is possible to increase the accu...

Page 18: ...pper limit For example ACTION DISPLAYS Press Pst PST nEt if currently in the weighing mode Press U Wt Units PST cnt to toggle from weighing to counting Press Print Hi cnt 0 3 2 3 4 The current high co...

Page 19: ...counting These data should be entered against a particular PLU before the weighing process starts so that the desired PLU s can be recalled during the weighing process The data can be stored and recal...

Page 20: ...haracters in total spreading over both the displays UNIT WEIGHT and COUNT Press Print to save the PLU x x x x x x The display will go back to the normal mode Note Use the key to go back to the previou...

Page 21: ...O 7 P Q R S 8 T U V 9 W X Y Z 0 _ Where _ is a Space Not underscore The limitations of the 7 segment display sometimes make it difficult to display some letters The characters and the displayed symbo...

Page 22: ...ing with the Tare and Unit Weight previously entered x x x x x x x x x x If the PLU key is held down after the numeric entry it will show the description as long as the key is pressed In this example...

Page 23: ...the self test when the power is turned on This will allow the user to set the way he wants the scale to work by choosing specific values from some options Press the U Wt Units key to scroll through th...

Page 24: ...nly is enabled Un I t UnI t Lb Lb only is enabled Print Au oFF Prints only when the Auto Accumulation is set to off Au on Prints only when the Auto Accumulation is set to on P Cont Sets the RS 232 int...

Page 25: ...ed the battery life will be reduced When the battery needs charging the arrow above the low battery symbol under the Weight display will turn on The battery should be charged as soon as the arrow abov...

Page 26: ...odd parity selectable No Parity Connector style needed 9 pin d subminiature socket Pin 2 Input Pin 3 Output Pin 5 Signal Ground Sample of output Using M function Using PRINT function LOCAL SCALE ID 12...

Page 27: ...cale memory to be used T Tare current weight value T123 456 preset tare value is 123 456 Z Zero the display P Print using selected format M Store current results into memory and print MR Recall memory...

Page 28: ...ING RS 232 INTERFACE This will allow the scale data to be sent from a PC program as well as from the keypad The most common PLUs can be stored and recalled from the scale memory Other PLU data can be...

Page 29: ...elect the weighing unit to be used for setting the calibration for the scale The arrow in the Weight window will indicate the unit selected Press the Print key to continue tEch Uni t You will enter th...

Page 30: ...is greater than the permissible value typically 4 of maximum capacity when power is turned on or when the Zero key is pressed Weight on the pan when turning the scale on Excessive weight on the pan w...

Page 31: ...rint Pi n Select the scale to be set up by using the Local Rem key Press the Print to enter the technical section for that scale t Ech Lo c A L t Ech r E mo t E Use the U Wt Units to select the weighi...

Page 32: ...Autozero tracking range Select from 0 5d 1d 2 4 d Press the U Wt Unit to go to next menu use Print key to enter Use U Wt Unit to increment the values then Print 0 Auto Zero auto range at power on Sel...

Page 33: ...tance In order to provide further assistance the supplier will need the following information which should be kept ready A Details of your company Name of your company Contact person s name Contact te...

Page 34: ...t is not returned in the original packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment wh...

Page 35: ...tion against harmful interference when the equipment is operated in a commercial environment The equipment generates uses and can radiate radio frequency energy and if not installed and used in accord...

Page 36: ...tronic Scales for Medical use Retail Scales for price computing Adam Equipment Co Ltd Bond Avenue Milton Keynes MK1 1SW UK Phone 44 0 1908 274545 Fax 44 0 1908 641339 e mail sales adamequipment co uk...

Reviews: