Page 4: ...set to verify counts up to 60000 divisions All indicators are supplied with a RS 232 bi directional interface and real time clock RTC The BCT indicator has a sealed keypad with colour coded membrane s...

Page 5: ...odels Model name BCT 35a BCT 65a BCT 130a BCT 165a BCT 330a BCT 660a Maximum Capacity 35lb 16kg 65lb 30kg 130lb 60kg 165lb 75kg 330lb 150kg 660lb 300kg Readability 0 001lb 0 5g 0 002lb 1g 0 005lb 2g 0...

Page 6: ...ss when the backlight is used Interface RS 232 Bi directional Display 3 displays showing 6 6 7 digits Scale housing Indicator ABS plastic Platform Stainless steel Overall dimension BCT 16 32 60 35a 65...

Page 7: ...perature Do not place in direct sunlight or near air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Avoid unstable power sources Do not use near large user...

Page 8: ...point PST CE Clear the preinstall value M Add all the quantities and store the max Total Number of Additions is 99 AVG On Off the automatic average function QTY PST Preinstall the High low Limit value...

Page 9: ...t and shows the results This is the net weight Entering a value using the keypad will store that as the tare value 0 Zero Sets the zero point for all subsequent weighing to show zero 5 0 DISPLAYS The...

Page 10: ...Tare Tare displays the deduction of the container weight M M Totaliser If the piece weight is smaller than Minimum Sampling Weight will be displayed In order to clear the symbol increase the size of t...

Page 11: ...displayed Press Tare to tare the scale Once the scale stabilises it will display the net weight and the NET sign will be displayed As a product is added only the weight of the product will be shown Th...

Page 12: ...press the M key in order to alternate between the two Once selected press the Q TY PST key to move to the next setting CHLn0d H L should now appear on the display Press the M key to set the check ala...

Page 13: ...e quantity is shown on the quantity display and enter the counting mode automatically The larger the sample weight is the more accurate the quantity will be With both the Unit weight and Quantity disp...

Page 14: ...E to delete the selected stored value When the scale shows all accumulated data press PST CE all accumulated data will be deleted In weighing mode press PST CE all accumulated will be deleted 6 5 SETT...

Page 15: ...letter input mode Now the user can input a letter by using the numeric keypad Press 2abc once the display will now show A and blink press once again the display will show B and so on After the letter...

Page 16: ...succeeds this will show Success The user can then set the next PLU DOWNLOAD MULTIPLE PLU BY TABLE RECOMMEND Use table edit software such as Excel WPS Numbers to new built a file then input PLU data by...

Page 17: ...nding sub parameter setting For example in T1 FC press 3 the display will jump to T3 bps Press the M key use to choose the right parameter options 7 1 RS 232 PARAMETERS The RS232 parameters are divide...

Page 18: ...OFF when pre inputting the tare value ON OFF F6 UNT Selecting the Weighing Unit Kg lb oz g F7 FIL Filter speed settings ON OFF F8 ZPE To set if the scale can alarm when weight is 0 ON OFF F9 FAL On me...

Page 19: ...total quantity window DXXXX Division value dp xxx Open or close the dual division CU xx The unit of capacity and calibration P3 LIN X Multi range calibration User can set multi range calibration on of...

Page 20: ...on When this parameter lost user can input the value by number key which been noted to calibration without weight Press M key the digit of total weight window will keep blinking Then input the value a...

Page 21: ...cale on using the rocker switch at the right back hand side of the indicator The display will show Enter 123456 which is the default passcode and you should see the following screen Press the Print Sa...

Page 22: ...rmal multiples To change the flashing division value press the M key repeated pressing of the M key cycles the values round again Once you are happy with the division press the PLU key you will then s...

Page 23: ...ht button clears any entered value Press the PLU key to show the zero A D counts when the stable indicator is showing press the PLU key to accept the zero point The screen should look similar as follo...

Page 24: ...done through RS 232 connectivity Labels can also be printed via the built in printer when in the accumulation recall function and in parts counting 9 1 LABEL EDITING COMPUTER SOFTWARE The BCT is supp...

Page 25: ...1 Connect the scale to the PC using the RS 232 cable provided this is so the customised label can be downloaded straight to the indicator after completion 2 Start up the label editing software Test E...

Page 26: ...l can be customised and edited to the desired preference From here select to start a new label design open a previously saved template or save a template to your PC Printer Chose the type of printing...

Page 27: ...variable to add to the label For example net weight Net weight will appear on the label as The added information can be moved and p y the label by clicking and holding down The text can also be furthe...

Page 28: ...Text picture icon in the editing tools section and add text in the TEXT section 9 1 6 ADDING BARCODES Bar codes can be added to the label which are capable of holding various weighing data Left click...

Page 29: ...lers usually use EAN13 Readable Enable or Disable the Print out of the text below the barcode Rotation Rotation angle 0 clockwise Text Can insert this variable EAN13 barcodes must be numeric and 12 di...

Page 30: ...message of confirmation will appear click OK to confirm 9 2 LABEL DOWNLOAD PROCEDURE VIA RS 232 CABLE Save your final label design in preparation for download via RS 232 to the BCT by pressing the sav...

Page 31: ...ight and count Specifications Connector The scale can be set to print text in English French German or Spanish See the RS 232 parameters section for details All lines end with line feed lf and carriag...

Page 32: ...ights and lb for pounds G W 1 234 Kg Net Wt if net weight is displayed Item barcode lf cr Includes 2 line feeds with carriage return lf cr at beginning and end of the form DATE 12 09 2006 TIME 14 56 l...

Page 33: ...Piezas Number of weighings added to subtotals No Nb Anzhl Num Total weight and count printed Total Total Gesamt Total Print date Date Date Datum Fecha Print time Time Heure Zeit Hora 10 1 INPUT COMMA...

Page 34: ...ss ID to escape and return to normal weighing mode 10 3 AUTO SLEEP FUNCTION To set the auto sleep function you will need to enter the Other function parameter setting in the User parameters see sectio...

Page 35: ...recommend that you do not always connect to the power supply 11 3 BACKLIGHT FOR LCD The backlight of the LCD can be set to be 1 ON at all the time 2 ON only when a weight is placed on the scale or 3 T...

Page 36: ...port ERROR CODE DESCRIPTION Solution ADO Over A D resolution range Remove the weights of the pan or send back to the agent ADL Over A D resolution range Remove the weights of the pan or send back to t...

Page 37: ...eady A Details of your company Name of your company Contact person s name Contact telephone e mail fax or any other methods B Details of the unit purchased This part of information should always be av...

Page 38: ...faulty installation unauthorised modifications or attempted repair or failure to observe the requirements and recommendations as given in this User Manual This product may include a rechargeable batt...

Page 39: ...ercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio...

Page 40: ...Adam Equipment Company 2019 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Reviews: