Ada GENESIS SYSTEM Design & Installation Manual Download Page 10

- 9 -

Control Options (cont.)

2

MC-1001 Single Gang Keypad with Volume Control - The MC-1001
is one of the most popular Genesis System controls in that both the
control buttons and rotary volume control are housed in a single-
gang wall box.  The MC-1001 is fitted to an all-metal wall plate that
has fixed screw holes.  The wall box must be completely square as
the MC-1001 provides no play once installed.  The standard wall
plates available for the MC-1001 are white and black anodized.
Custom wall plates are available in brass, chrome, and black
chrome.  The MC-1001 with a clear anodized wall plate is ideal for
painting.  Additional custom metal finishes such as gold-plated,
nickel, and bronze are also available.

3

MC-1010 Double Gang Keypad with Volume Control -
The MC-1010 Keypad fits into a double-gang box and
also includes a rotary volume control.  The MC-1010 is
fitted to an all-metal wall plate that is mounted into a
double-gang wall box.  The wall box must be com-
pletely square as the MC-1010 provides no play once
installed.  The standard wall plates available for the
MC-1010 are white and black anodized.  Custom wall
plates are available in brass, chrome, and black chrome.
The MC-1010 is also ideal for painting in a clear
anodized wall plate.  Additional custom metal finishes
such as gold-plated, nickel, and bronze are also avail-
able.

4

The MC-11.5 Keypad is used in conjunction with the ZS-3 Zone
Splitter to provide both room on/source selection, room off/system
off, Genesis source transport control, and volume control of a
specific Genesis Room (Zone Area).  The MC-11.5 and ZS-3
combination also permits these same functions to be controlled
via the wireless infrared remote control, the MC-0011.   The MC-
11.5 Keypad, in addition to the standard three source buttons and
room off button, also includes both Volume Up and Down buttons
as well as an IR receiver.  The ZS-3 incorporates a stereo
electronic step autoformer, and the IR decoder board for the MC-
11.5.  The MC-0011 IR Remote Control provides the same
functions of the MC-11.5 in a wireless hand-held control.  Please
note, due to the additional IR and volume control aspects of the
MC-11.5 require it to be wired with a twelve conductor control cable to the ZS-3.  The
ZS-3 connects to the Genesis using the recommended eight conductor cable.  When
using the ZS-3, it is important to remember that the ZS-3 operates exactly like a 50 Watt
autoformer.

CASS

ROOM

OFF

CD

FM

CD

CASS

ROOM

OFF

FM

CD

DSS

ROOM

OFF

FM

VOL

DN

VOL

UP

Summary of Contents for GENESIS SYSTEM

Page 1: ...tes Inc 602 610 Mamaroneck Ave White Plains NY 10605 914 946 9595 FAX 914 946 9620 C e l e brating Twenty Y e a r s O f M a nufacturing Exce l l e n c e GENESIS SYSTEM DESIGN INSTALLATION DEALER MANUA...

Page 2: ...nections 14 External Power Amplifier Options 15 Power Amplifier Automatic AC Switching 16 Keypad Control and Speaker Cable Wiring 17 Multiple Parallel Keypad Speaker Connections 18 GRE 2 Genesis Room...

Page 3: ...oth Never clean with furniture wax benzine insecticides or other volatile liquids since they may corrode the face plates POWER LINES An outdoor antenna should be located away from power lines PERIODSO...

Page 4: ...ystem to better fit your client s lifestyle and design esthetic Furthermore many accessories allow you to truly customize a system without having to include expensive home automation type controllers...

Page 5: ...e three sources on one at a time when a particular source is selected 5 Main AC Switched Outlet The Genesis includes a Main switched AC outlet which can be used to engage an equalizer when any one roo...

Page 6: ...n as independent Genesis rooms would be for example the master bedroom and master bath as one might want to turn on music in the bathroom without disturbing someone who might be sleeping in the bedroo...

Page 7: ...sis s front panel The SOURCE button s LED will be lit when that source is selected If the Record Power switch is in the on position all three source button LEDs will be lit indicating that all three s...

Page 8: ...and seeing the CD button s LED on you will automatically know that the CD player is in use elsewhere in the home To listen to the CD player simply press the CD button To listen to a different source p...

Page 9: ...pads for control without status feedback In these cases the LED indicators on the keypad will not illuminate at all e If you have a three conductor cable with shield drain along with the speaker wires...

Page 10: ...leinbrass chrome andblackchrome The MC 1010 is also ideal for painting in a clear anodized wall plate Additional custom metal finishes such as gold plated nickel and bronze are also avail able 4 The M...

Page 11: ...romtheaboveformat acustom silk screened plate will need to be created Each custom plate carries a surcharge 10 GRE 2 Genesis Room Expander The GRE 2 is used to break a particular Genesis room area int...

Page 12: ...Ds are lit If you exit the program mode and press no other front or rear panel buttons the second and fourth LEDs are lit Pressing any front panel transport button will turn all LEDs off To program IR...

Page 13: ...rces into the Genesis you can verify the functions providing the source components are available To verify the program ming 1 Connect an IR flasher to the Genesis s IR output jack and aim it stick it...

Page 14: ...Obtainan1 8 male to male mini phono jack mono 2 Plug this 1 8 male to male mini jack into the Genesis s IR Output port and the IRS 8 s IR Input port 3 Connect the IR emitters flashers to each source c...

Page 15: ...E THREE MAIN OUTLET A C I N P U T STANDBY 2 10A S B AMP 5A S B MAIN 7 5A S B SW AC 2 5A MAX 1 2 3 VAR OUT REC OUT AMP IN LOOP AUDIO INPUTS PROGRAM 2ND FUNCTION 1ST FUNCTION POWER ON IR ERROR PGM IR SE...

Page 16: ...16 pairs of 8 speaker in parallel 32 speakers The PF 201 while providing 60 Watts per channel at 8 kicks out over 240 Watts per channel at 1 2 The PF 201 is fan cooled and provides high current outpu...

Page 17: ...s variable audio s i g n a l preamplified audio signal for its own in ternal ampli fier used for other rooms you will need to split the p r o c e s s o r loops output to both the e x t e r n a l power...

Page 18: ...ation from the mainframe while running two separate 2 Conductor speaker cables to the speakers from the keypad location one to the right channel speaker and one to the left channel speaker 1 2 3 4 5 6...

Page 19: ...nds running each keypad s control cable individually home to the system mainframe This will permit some flexibility should the client wish to expand the system at some later date and will also provide...

Page 20: ...rol Input From Genesis Control Output 1 To Keypad Control Output 2 To Keypad GRE 2 Genesis Room Expander GRE 2 Genesis Room Expander Connections The Genesis Room Expander GRE 2 offers independent room...

Page 21: ...Shouldyourclientbeconcernedthat kid s from the neighborhood may be running through the backyard and thereby open to toying with the system you could locate an MC 1111 Keypad inside the home near the d...

Page 22: ...OR PGM IR SENSOR IR OUTPUT WARNING RISK OF HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTIONS AVERTISSEMENT ENERGIE ELECTRIQUE DANGEREUSE FAIRE DES CONNEXIONS PROPRES POUR L HAUTPARLEUR VOIR LA NOTICE D...

Page 23: ...ur video sources or the source component selected on the Genesis The diagram to the right details these connections You can even add an additional audio only source component to the home theater syste...

Page 24: ...0 V PTM 6150 POWER AMP CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR MADE IN U S A WARNING RISK OF HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTIONS AVERT...

Page 25: ...g Since the Genesis incorporates independent source switching in its most basic setup this source switching will need to be bypassed somewhat permitting the home theater system to also engage the sour...

Page 26: ...SUPPLY CORD BEFORE SERVICING ATTENTION DEBRANCHER AVANT LE DEPANNAGE Manufactured under license from Lucasfilm Ltd Lucasfilm and THX are registered trademarks of Lucasfilm Ltd CAUTION DO NOT SHORT OUT...

Page 27: ...of an MC 1010 s circuit board double gang keypad 3 5 wide by 2 8 inches tall and will fit some double gang masonry boxes but may not fit all types For MC 100 OD All Weather Outdoor Keypads double gan...

Page 28: ...place Unlike other rack plate manufacturers components rack mounted by ADA are completely mounted to the plate and do not just sit on a shelf and slide through an opening Also because the plate is cu...

Page 29: ...s result from sloppy wire termination Home Run Wires Prior to installing any of the equipment into the rack ADA suggests toning out the keypad IR speaker and any other cables run from remote rooms to...

Page 30: ...t the mainframe or at a location with multiple keypads it is strongly recommended to label the wire Thus as you return to the job site for the final installation you will be able to easily identify th...

Page 31: ...wires and cables which interconnect all the components For more information on rack hardware available from ADA see page 27 Step C System Mainframe AC Wiring Running the high voltage cables prior to a...

Page 32: ...ion go to pages 18 19 Step H Control Cable Connections to Keypads Genesis At this time you should have already toned out control cable lines to verify that no shorts exist on the cables and that conti...

Page 33: ...when the speaker wires have been run directly from the speakers to the system mainframe The MC 11 5 controls use the same control cable as the Millennium System ZS 3 GENESIS ZONE SPLITTER TO MC 11 5 K...

Page 34: ...provided by ADA and included with the MC 1001 One end of this cable has an eight pin female Molex type connector This connector plugs into the bottom of the MC 1001 When holding the keypad such that t...

Page 35: ...ed for readout would not be used While the control functions would remain the same for a keypad wired with only five conductors the keypad s LEDs would not light up at all If you are planning to wire...

Reviews: