burners and forks) should be removed immediately. Do not start the device if the
heating chamber is not cleaned!
If not all burners are used, we always use the lowest ones. No dripping fat should get
into unused burners. It contains spices that can destroy ceramics. After each prolonged
immobilization, the device should be "burned out" for a period of 5-10 min. Stainless
steel surfaces can be cleaned with suitable chemicals. The forks should also be kept
permanently clean (e.g. by dipping them in water for several hours).
Ceramic furnaces are not cleaned mechanically or with chemical agents. We do not use
water or steam jet. We let them burn (automatically).
Make sure you choose the right cleaner, and do not use steel wool or other cleaning
tools or cleaning agents / disinfectants containing chlorine, bromine, iodine or
ammonia, as these substances will damage stainless steel and shorten the useful life of
the device.
Only clean the appliance when it is cold - otherwise there is a risk of burns.
5.3. Solving problems
Ceramic furnaces glow faintly or blue
Check the gas pressure or to clear the nozzle. Clean the nozzle with cleaning sticks
attached to the device. If contamination is very large unscrewed the nozzle from
housing and clean the nozzle in the wash solvent and then purged so that the light hole
was perfectly round.
The spits do not rotate properly
Loose drive chain. In such a case loosen the screws fastening the motor to the housing
and tighten the motor in the oblong holes. Tighten the fixing screws.
The burner goes out after lighting and releasing the gas valve.
Replace the thermocouple. To replace a used thermocouple, unscrew one end at the gas
valve and the mounting screws on the other side against the wall of the device housing.
Install the new thermocouple in the reverse order.