ADA GASTROGAZ ADA 1 Operating Manual Download Page 11

11 

 

• When using a device for liquid gas, such rooms must not be below ground level, i.e. in 
the  basement  or  basement,  and  the  temperature  of  the  room  where  the  B  /  P  gas 
cylinder is located must not exceed 35 ° C. 
 
In  order  to  ensure  proper  ventilation  at  all  times  inside  and  around  the  gas  cylinder 
compartment,  obtain  a  constant  supply  of  fresh  air  and  prevent  the  accumulation  of 
unburned  gases,  make  sure  that  the  device  and  the  cylinder  are  close  to  the  opening 
window;  if  the  equipment  is  in  a  closed  room,  it  must  be  installed  with  an  efficient 
ventilation hood or shaft. 
 

Warning! 
Pursuant  to  the  applicable  provisions  of  the  Building  Law,  liquefied  gas  may  not  be 
used in the building in which the natural gas installation is located. 

 
 
The appliance can be powered by 11 and 33 kg gas cylinders. The maximum dimensions 
with a reducer for a 11 kg cylinder are 65 x 35 x 35 cm, while for a 33 kg cylinder it is 130 
x 37 x 37 cm. A liquid gas cylinder should: 
• put at least 1.5 m from heat radiating devices, 
• cylinders should not be placed in the vicinity of other sparking devices, 
• install cylinders in an upright position and secure them against falling, falling over or 
accidental displacement. 
 
Gas supply pipes or hoses should meet applicable national requirements and should be 
periodically checked and replaced if necessary. 
 
 

When installing the appliance, observe the following applicable regulations: 

• Standards, regulations, building and fire regulations. 
• Health and safety regulations. 
• Regulations issued by gas suppliers, which should also be used to confirm the approval 
of the installation of the device. 
• Standards, regulations, ordinances for gas installations and gas-powered equipment. 
• Standards, regulations, ordinances regarding ventilation. 

 

The appliance installer should: 

• Have a qualification certificate. 
•  Read  the  information  on  the  rating  plate.  Compare  the  information  with  the  gas 
delivery conditions at the place of installation. 
• Check the gas valve connections for leaks. 
• Check the effectiveness of all components of the device's operation. 
• Familiarize the user with the operation of the device. 
 

Summary of Contents for ADA 1

Page 1: ...I A N C E S A N D I N O X F U R N I T U R E OPERATING MANUAL Gas Rottiseries v 4 2 ADA 1 ADA 2N ADA 2 ADA 3 ADA 4 ADA 5 ADA 6 ADA 7 ADA 8 Maszyny i Urządzenia Gastronomiczne ADA GASTROGAZ ul Kolejowa 9 66 10 Sulechów Poland www ada gastrogaz com ...

Page 2: ...ng and reliable operation of this rotisserie ADA gas rotisseries are certified appliances which means that they have among others CE mark and are covered by compliance procedures verified by the Oil and Gas Institute in Krakow National Research Institute They meet the requirements of Regulation EU 2016 426 of the European Parliament and of the Council of 9 March 2016 relating to appliances burning...

Page 3: ... Gas installation 9 4 2 Electrical installation 10 4 3 Appliance installation 10 4 4 Assembly order 12 4 5 Burner s adjustment 13 5 Instructions for use and maintenance 14 5 1 Using the appliance 14 5 2 Cleaning the appliance 14 5 3 Solving the problems 15 5 4 First aid 16 5 5 Warnings 16 6 Conditions of the guarantee certificate 18 Guarantee Certificate 19 ...

Page 4: ...oses for which it was designed Any other use can be dangerous to the operator The manufacturer is not liable for damages resulting from improper use Parts that have been marked protected against unauthorized interference must not be adjusted by the user Installation of the device should be carried out by authorized persons according to the manufacturer s instructions and in accordance with applica...

Page 5: ...or other meat joints Rotisserie ADA can be mounted on catering trailers catering cars as well as used in bars shops and other catering establishments Our machines are characterized by high durability reliability in operation small gas consumption and a short roasting time Fig 1 Gas rottiserie ADA 5 ...

Page 6: ...elected appropriate nozzles Rotisseries ADA have 2 sets of spits First row of spits is situated directly on the front of the burners Second row is situated slightly closer to the door and located in gaps between the first rows of spits Fig 2 Construction diagram of ADA gas rotisserie 1 Engine and light switch 2 Gas adjustment knobs 3 Gas burner 4 Roof with chimney 5 Drip tray 6 Drain Valve 7 Therm...

Page 7: ...side the housing on the right page lighter Additional equipment optional baskets for legs or knuckles rack on wheels or without and with a drawer cabinet on wheels or without and with a drawer or without Gas Chicken Rotisserie ADA 1U Technical data ADA 1U Thermal power kW 7 Number of burners pc 2 Propane gas consumption kg h 0 49 Natural gas consumption m3 h 0 73 Number of chickens pc 6 8 Number o...

Page 8: ...140 Chimney diameter mm 132 132 132 132 Chimney height mm 100 100 100 100 Gas Chicken Rotisseries ADA 4 ADA 8 Technical data ADA 4 ADA 5 ADA 6 ADA 7 ADA 8 Thermal power kW 20 25 30 35 40 Number of burners pc 4 5 6 7 8 Propane gas consumption kg h 1 60 2 00 2 40 2 80 3 20 Natural gas consumption m3 h 2 08 2 60 3 12 3 64 4 16 Number of chickens 1st row pc 20 24 25 30 30 36 35 42 40 48 Number of chic...

Page 9: ...as type may only be carried out by authorized persons To change the type of gas replace the set of gas burners and adjust the pilot burner Warning The chimney reaches a high temperature which is why you should pay attention to maintaining a proper distance from the wall The device should be placed in such a way as to ensure ventilation to an appropriate exhaust hood or ventilation system This is e...

Page 10: ... is very important for the safety of the user and the efficient operation of the air exchange system must not be prevented Based on these regulations the room in which the device will be installed should meet the following requirements and have Efficient supply and exhaust ventilation ensuring air exchange of at least 37 5 m3 h for each kilowatt of thermal power of the gas device the minimum dimen...

Page 11: ...ould put at least 1 5 m from heat radiating devices cylinders should not be placed in the vicinity of other sparking devices install cylinders in an upright position and secure them against falling falling over or accidental displacement Gas supply pipes or hoses should meet applicable national requirements and should be periodically checked and replaced if necessary When installing the appliance ...

Page 12: ...k on the rating plate to which gas type the appliance is adapted and whether it corresponds to the type of gas in the gas installation propane butane B P or natural gas E 4 Make the connection in accordance with the following rules connection to natural gas should be made a rigidly using seamless pipes steel or copper b or using a metal braided hose with a CE safety certificate connection of B P f...

Page 13: ... Gas supply pipes or hoses should meet applicable national requirements and should be periodically checked and replaced if necessary 4 5 Burner s adjustment Burner power and gas savings can be adjusted by the regulation of the needle gas valve located on the front the rotisserie under gas knob Warning Do not twist the needle to the left more than three full turn s of screwdriver Further loosening ...

Page 14: ...purged from air After about 5 minutes burner should glow a raspberry colour If you do not get this colour it means that the burner does not get proper power leaky installation clogged nozzle faulty pressure regulator or pressure drop gas supply installation spit Defect must be reported to distributor Fig 5 Marking on the gas valve knob 5 2 Cleaning the appliance Internal and external walls do not ...

Page 15: ...bromine iodine or ammonia as these substances will damage stainless steel and shorten the useful life of the device Only clean the appliance when it is cold otherwise there is a risk of burns 5 3 Solving problems Ceramic furnaces glow faintly or blue Check the gas pressure or to clear the nozzle Clean the nozzle with cleaning sticks attached to the device If contamination is very large unscrewed t...

Page 16: ...epairs by yourself leave rotisserie unsupervised when is working store near combustible materials allow children to operate the barbecue or people not familiar with this instructions use in places with poor ventilation system install in areas that hinder its operation Use an open flame electrical and mechanical equipment that may cause an electrical spark if you can smell gas In this case you shou...

Page 17: ...ctrical equipment contributes to avoiding consequences harmful to human health and the environment resulting from the presence of hazardous components and improper storage and processing of such equipment At the end of the life of the equipment return the device to the appropriate institution that deals with the disposal of the devices On behalf of the manufacturer the contract regarding the organ...

Page 18: ...some parts in gas appliances light bulb thermocouple burner protection grid ceramic plate glass gasket in electrical equipment light bulb glass gasket 5 In the event of any faulty operation of the device during the warranty period immediately inform the Seller Complaints should be made in writing by fax e mail or post 6 Both the manufacturer and the seller shall not be liable for any direct or ind...

Page 19: ...FICATE Appliance Fabric number Manufacturing date Manufacturer quality control sign Date of sale Sign and stamp of seler No The date of the declared complaint The date of the repair The type of the repair Sign and stamp ...

Reviews: