![ADA GASTROGAZ ADA 1 Operating Manual Download Page 11](http://html1.mh-extra.com/html/ada-gastrogaz/ada-1/ada-1_operating-manual_2845734011.webp)
11
• When using a device for liquid gas, such rooms must not be below ground level, i.e. in
the basement or basement, and the temperature of the room where the B / P gas
cylinder is located must not exceed 35 ° C.
In order to ensure proper ventilation at all times inside and around the gas cylinder
compartment, obtain a constant supply of fresh air and prevent the accumulation of
unburned gases, make sure that the device and the cylinder are close to the opening
window; if the equipment is in a closed room, it must be installed with an efficient
ventilation hood or shaft.
Warning!
Pursuant to the applicable provisions of the Building Law, liquefied gas may not be
used in the building in which the natural gas installation is located.
The appliance can be powered by 11 and 33 kg gas cylinders. The maximum dimensions
with a reducer for a 11 kg cylinder are 65 x 35 x 35 cm, while for a 33 kg cylinder it is 130
x 37 x 37 cm. A liquid gas cylinder should:
• put at least 1.5 m from heat radiating devices,
• cylinders should not be placed in the vicinity of other sparking devices,
• install cylinders in an upright position and secure them against falling, falling over or
accidental displacement.
Gas supply pipes or hoses should meet applicable national requirements and should be
periodically checked and replaced if necessary.
When installing the appliance, observe the following applicable regulations:
• Standards, regulations, building and fire regulations.
• Health and safety regulations.
• Regulations issued by gas suppliers, which should also be used to confirm the approval
of the installation of the device.
• Standards, regulations, ordinances for gas installations and gas-powered equipment.
• Standards, regulations, ordinances regarding ventilation.
The appliance installer should:
• Have a qualification certificate.
• Read the information on the rating plate. Compare the information with the gas
delivery conditions at the place of installation.
• Check the gas valve connections for leaks.
• Check the effectiveness of all components of the device's operation.
• Familiarize the user with the operation of the device.