installation of a hiGh or loW hEatinG circuit
With control unit
SChEMATIC DIAGrAM
The heating (high temperature or floor heating) is controlled by the AF200
outside temperature detector supplied with the Control Unit and by the RFF
room detector or RS Zone Unit.
The detectors are connected to a controller that can be built into the boiler.
This controller operates the four-way valve and the circulator depending on
requirements (calculated from the outside temperature) and on the start
temperature measured by a third detector.
- The system provides a high level of comfort as the start temperature is
constantly adapted to heating requirements.
- Built-in timer with setting of heating times (day) and lower temperature
times (night).
- The room detector allows the user to adjust the comfort setpoint to their
specific requirements.
Equipment required
as options
codes
descriptions
10800030
Control Unit :
Supplied with an AF200 outside detector and a 2 kΩ KVT bulb sensor
10800108
AF200 2 kΩ outside temperature sensor :
Included with control unit
ou
10800056
RS Zone Unit :
Remote c room sensor
10800120
RTF room sensor
10800045
VF202 2 kΩ contact sensor :
For outlet on controlled circuit
10510900
RAM 5409 contact thermostat :
Obligatory to protect floor heating circuits
10800199
ARA661 servomotor :
Motor for four-way valve