4
5
PART NAMES AND WIRING
Be careful not to reverse the battery poles. Doing so can cause the ESC to fail.
If the sensor cable is not connected, has not been properly inserted, has been
disconnected, or is loosely connected, all the LEDs will blink (highspeed
blinking). While in this state, all operations will not be received. If this occurs,
check the connection for the sensor cable or replace the cable.
When inserting the connector, pay attention to the way in which it being inserted.
If inserted backwards, the device will not operate.
Be sure to match the cables to the symbols A, B, and C on the ESC. Failure to
follow this precaution can result in loss of control over the motor speed, or
subject the ESC and motor to large currents. Unlike brushless motors without a
sensor, swapping these cables does not change the rotating direction of the
motor. If necessary, change the direction of rotation at the ESC
※
.
※
To switch the direction of rotation, it is essential to have the rotation direction
change function in the ESC. This machine has this function (P.16)
When replacing the motor cable, use a soldering iron with a broad tip and high
output rating (as high as 60 W) and work swiftly. A soldering on with the low
output rating will not melt enough of the solder resulting in a poor soldering
connection which can cause cables to loosen under vibration or loose
connections. Also, subjecting the internal parts to excessive heat over prolonged
periods (10 seconds or more) can damage them. (Be careful not to shortcircuit
the terminals with solder)
Be sure to use screws with a length of 8 mm or less to secure the motor to the
motor mount. If the screw is too long, it may interfere with parts inside the motor,
resulting in malfunctions such as short circuit.
WARNING
WARNING
WARNING
WARNING
WARNING
• POWER BUTTON
• LINK TERMINAL
• SET BUTTON
• COOLING FAN CONNECTION TERMINAL
It is the button to turn the unit ON or OFF.
It is used for setting change in the XARVIS XX main unit. It is also used to switch
between "ESC mode" setting of the main unit, and "Link mode" setting with TAO
II.
ACUVANCE optional cooling fan or fan connection terminal with our motor.
It doesn't matter if you use either terminal
①
or
②
.
Since it is designed exclusively for ACUVANCE cooling fan, other manufacturers'
cooling fans cannot be used.
(If you use a fan of a different brand, the fan may be damaged.)
Terminal for communication with TAO II, Ne-St. Air-Link Adapter (OP-15065),
S.BUS Adapter (OP-15067), etc. are also connect here.
DANGER
To prevent fumes, fire, or burns
1 2
RX
FAN
SENSOR
- + S
Please connect as
shown below
Sensor cable
Battery cables
Motor Cable C
Motor Cable A
Motor Cable B
XARVIS XX body
Sensored Brushless Motor
RX Cable
POWER button
SET button
[Behind]
Reverse
connection
alert LED
(see P.22)
The throttle channel(CH2)
from the receiver
Capacitor
RX Terminal
Sensor
Cooling
FAN
②
Rear Layout
Side Layout
LINK terminal
- + S
FAN
Cooling
FAN
①