background image

Prosody compact PCI installation guide 

1 Introduction 

1.1 General 

This document is the installation and user guide for the Aculab Prosody cPCI card. The base 
model of the Aculab Prosody cPCI card is a speech-processing card with the options of 2 or 4 
Prosody modules. Four E1/T1 ports and a signalling DSP module can be added to increase the 
functionality of the card. 

 

This introductory section of this document provides a general description of the Prosody cPCI 
card, and it's features and facilities. 

 

The design of the Aculab Prosody cPCI card allows Network connections to be made via RJ45 
connectors on the front edge of the card, or via an optional ‘transition module’ offering RJ45 
connectors at the rear of the Compact PCI

© 

chassis. The advantage of the transition module 

approach is that cards can be removed and replaced without disturbing the Network 
connections. 

 

CAUTION 

When the transition module is used for network connection, do not attempt to simultaneously connect to the network using the front 
panel RJ45 connectors. Only one connector may be used for each network port. Misuse may invalidate Telecommunications approvals. 

 

To avoid problems when replacing or swapping cards, care must be taken to ensure that the 
replacement card has the same functionality as the card it replaces. This applies to the number 
of network ports on the PM module, if fitted, and the type of signalling DSP, if fitted. PM 
modules are available with up to four network ports. Signalling DSP modules are available with 
up to four DSPs, (one per port). 

 

DSP65

module

 

 

The Aculab Prosody cPCI card and Transition Module with Line Interface Module and optional signalling DSP. 

 

The serial number of the Prosody

®

 cPCI card may be used when configuring the device driver to 

uniquely identify a Prosody

®

 cPCI card in the system. The serial number of the card is located on 

the reverse of the card (no components) on the top edge and has the format P/N ACXXXX S/N 
XXXX WONXXX. Only the number XXXX following S/N is used during driver configuration, the 
other numbers are for Aculab use.  

 

This product is referred to as the 'Prosody cPCI card’ in this document unless the context 
requires a more specific term. 
 
 

Summary of Contents for Prosody

Page 1: ...MAN1360 Revision 2 2 3 Aculab Prosody compact PCI Installation Guide...

Page 2: ...It is important to check the current position with Aculab plc Copyright Aculab plc 2000 All rights reserved Document Revision Rev Date By Detail 1 0 Apr 2000 DMB First release 1 1 July 2000 DMB Approv...

Page 3: ...roval Information 12 3 1 Safety Warnings 12 3 2 EMC Compliance 12 3 3 Approval Details 12 3 4 Usage and Type 12 3 5 Environmental 12 3 6 Network Timing 13 3 7 Power Supply 13 3 8 Approved Functionalit...

Page 4: ...network using the front panel RJ45 connectors Only one connector may be used for each network port Misuse may invalidate Telecommunications approvals To avoid problems when replacing or swapping cards...

Page 5: ...tionally four E1 T1 ports on a plug in Line Interface Module LIM provide a means of connection to a digital telephone network The four port LIM is referred to as the PM4 LIM The H 110 CTBus expansion...

Page 6: ...ceive between 92 and 240 separate calls at a time Each individual ports driver is software configurable for either T1 or E1 75 or 120 Ohms An E1 port attaches to the 2Mbit digital system or Primary Ra...

Page 7: ...formation and control over the various stages of call progress This interface is accessed via a device driver that has been prepared for the operating system in use The PM4 Line Interface Module proce...

Page 8: ...CTBus 384 bi directional speech paths out of a possible 2048 Additionally any one source of speech or data may be distributed to a number of separate sinks but note that it is not possible via switch...

Page 9: ...fer to the Call Switch and Speech Driver Installation Guide for Signalling System information regarding the use of the PM4 Line Interface Module and Signalling DSP Note Only the expansion modules desi...

Page 10: ...PCI est pr sent compl te 2 4 German Installation der Karte Die Installationsprozedur f r die Erweiterungskarten ndert sich vom einen Hostcomputertypen zu einem anderen daher soll die genaue Installati...

Page 11: ...LED A red LEDs B C green PM4 Module LED detail While a port processor is in the reset state the LED A is on It will go out when firmware is downloaded to the port LED B turns on briefly during firmwar...

Page 12: ...tions in the USA Canada the UK Europe and Australia in conjunction with a PC that was compliant This does not guarantee that every EMC compliant PC will remain compliant when used with the card In ext...

Page 13: ...ry Warnings The CE Marking has been applied to the Aculab GroomerII to demonstrate compliance with the following European standards EN55022 and EN55024 for electromagnetic compatibility EN60950 for el...

Page 14: ...estriction on the use of the card apart from any restrictions listed in the appendices following Country Specific Information It is the responsibility of the user to ensure that all of the legal requi...

Page 15: ...llation Guide for the Prosody cPCI card These appendices should always be read in conjunction with the other sections of Instructions for Use The appendices are arranged in separate sections detailing...

Page 16: ...stalled in a UL listed cPCI bus based computer system Industry Canada Warnings The Industry Canada Label identifies certified equipment This certification means that the equipment meets telecommunicat...

Page 17: ...requency energy and if not installed in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cau...

Page 18: ...ndependent Operation of the network ports one or more ports attached to the public network Operational code running from RAM Speech Calls If the T1 card is used in an application that makes or answers...

Page 19: ...ild out setting is suitable for cables up to 133 feet between the card and the FCC IC or UL Listed CSU Network Cable Pinout The 8 contact RJ48 RJ45 Telephone Modular Plug on the cable between the card...

Page 20: ...Prosody compact PCI installation guide 20 Appendix C Approval Details For European Union Countries This section applies only to the 120 Ohm E1 version of the PM 4 module...

Page 21: ...ble or planned Approved functionality The following files are examples of the signalling software that has to be loaded into RAM for connection to the various types of network Mercury CAS PD1 PD1 UPR...

Page 22: ...rd or by any other suitable means such as independent testing Signal sources that do not guarantee compliance with this requirement must be conditioned by appropriate circuitry before transmission Car...

Page 23: ...nto the host equipment Failure to install the Prosody cPCI card in accordance with these instructions will invalidate the Approval 75 ohm Line Interface Each network port on the card carries one 30 ch...

Page 24: ...eed 6dB All that other apparatus shall comprise only apparatus approved for the purpose of connection between the apparatus and the network Cable wire and wiring accessories shall comply with Approval...

Page 25: ...ic environment this product may cause radio interference in which case the user may be required to take adequate measures No changes or modification to the Prosody PCI card are allowed without explici...

Page 26: ...Prosody compact PCI installation guide 26 Appendix D Approval Details for Japan...

Page 27: ...ependent Operation of the network ports one or both ports attached to the public network Operational code running from RAM Speech Calls If the T1 card is used in an application that makes or answers c...

Page 28: ...follows PIN SIGNAL FUNCTION Direction 4 LTT Transmit tip output 5 LTR Transmit ring output 1 LRT Receive tip input 2 LRR Receive ring input The cable and plug must be shielded types to ensure EMC comp...

Page 29: ...circuit use are also appropriate and other signalling systems are available or planned The Australian and NZ Approvals are only applicable when the Prosody cPCI card is used with Aculab supplied sign...

Page 30: ...interface port within the system If in any doubt seek competent advice All host equipment incorporating the E1 ISDN interface must be earthed Network Cable Pinout The 8 contact RJ45 Telephone Modular...

Page 31: ...ing of 120 channels to optional signaling DSP module Clocking Without PM4 module CT bus slave With PM4 module CT bus master supporting clock fallback Embedded processors 4 x Analog Devices ADSP 21062...

Page 32: ...hen local EMC testing of a system identifies the need for E1 T1 trunk cable clamping Europe USA Canada To Aculab Card To PSTN Ferrite Clamp RJ45 Nominal distance 1 inch The Ferrite clamp consists of t...

Page 33: ...recommendations G 703 G704 It is the interface between the ITS and the backhaul network switch EC Echo Cancellation ECTF Enterprise Computer Telephony Forum EMC ElectroMagnetic Compatability EN Europ...

Page 34: ...Access Memory REN Ringer Equivalence Number RJ Registered Jacks RJ11 6 position RJ45 8 position SELV Safety Extra Low Voltage SCBus Dialogic specific version of MVIP bus T1 American 1 55Mbits s 24 ch...