background image

Page 

3

 of 4

LED

Little Wall Pack | Pequeña Luz de Pared | Petite Applique

TOOLS REQUIRED FOR INSTALLATION

(not included)

/ HERRAMIENTAS NECESSARIAS PARA LA 

INSTALACIÓN

(no incluidas)

/ OUTILS REQUIS POUR L’INSTALLATION

(non inclus)

Ladder

/ Escalera

/ Échelle

Safety Glasses

/ Gafas de seguridad

/ Lunettes de  protection

Gloves 

/ Guantes

/ Gants

Silicone Sealant

/ Sellador de silicona

/ Agent d’étanchéité à base de silicone

Phillips Screwdriver

/ Destornillador Phillips

/ Tournevis Phillips

3.  Run the supply wires through the center hole in the back 

plate (Figure 2) and secure the back plate to the junction 

box using the provided screws and the slots in the back 

plate. Use the open slots that best fit the junction box.

Note: 

When using electrical conduit for supply wires (instead of junction 

box), connect the conduit directly to the back plate center hole or conduit 

entry ports (on EL and BB Models). The center hole and conduit entry 

ports are set up to accept ½” electrical conduit. Then secure back plate 

to the wall using wall anchors (not included). 

4. Connect fixture leads to junction box leads (Figure 3).

Note for EL Models:

 Power to the battery needs to be supplied using 

an un-switched power source (Figure 3). Power for regular illumination 

can be either switched or un-switched as needed.

a. Connect ground wire (green) from fixture to grounding 

conductor of supply circuit and secure with wire nut. For 

proper wire connections, place wire nut over wires and 

twist clockwise until tight.

b. Connect neutral wire (white) from fixture to neutral wire of 

supply circuit and secure with wire nut.

c. Connect hot wire (black) wire from fixture to hot wire of 

supply circuit and secure with a wire nut.

d. For EL Models: Connect the battery leads for battery 

backup function to be activated.

Note: 

 Always connect the green ground wire first. Individually cap any unused 

wires. Use UL listed wire connectors suitable for the size, type, and number of 

conductors. No loose strands or loose connections should be present.

STEP 3: INSTALL HOUSING                                                       

1.  Close the fixture by “hanging” the front housing to the back 

plate with the two tabs on the back plate (Figure 2). Then 

push the housing towards the back plate and tighten screw 

at the bottom of the fixture.

Note: 

Ensure no wires are pinched before tightening. Do not to over-

tighten the screw. 

2.  Apply caulking to the perimeter of the fixture between the 

housing and the wall (top and two sides) leaving the bottom 

side clear of any caulking (Figure 4). Caulking will prevent 

any water coming down the wall from entering the fixture.

STEP 4: RESTORE POWER                                                          

1. Restore power at the main fuse or circuit breaker box.

2. Check operation of fixture. 

Note for PE Models:

 Test fixture at night or block Photocell to turn 

fixture on. Cover the photo sensor with electrical tape, then turn power 

on and allow a couple of minutes for the sensor to activate the fixture. 

Then remove the electrical tape and the fixture will start to operate 

automatically when the ambient light is low enough.

Note for EL Models:

 When power is supplied to the battery the test button 

will light up indicating the battery is charging. Allow the battery to charge for at 

least 24 hours, then perform a short test by pushing the test button. The fixture 

will switch to battery mode and deliver about half the normal illumination. After 

the battery is fully charged (at least 48 hours of continuous power) a full 90 

minute test can be performed by cutting power to the fixture.

SAVE THESE INSTRUCTIONS: 

Protect yourself. Before 

installing, read the entire instructions carefully and save them 

for future reference.

DATE INSTALLED:

 __________________________________

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

WARNING: When using electrical equipment, basic 

safety precautions should always be used including the 

following: This product must be installed in accordance 

with the applicable installation code by a person familiar 

with the construction and operation of the product and the 

hazards involved. Neutral wire is required for three phase 

input.

CAUTION - Regarding EL Models: 

• Battery is rechargeable Ni-Cd type and must be recycled 

or disposed of properly. Do not use this battery driver 

with accessory equipment other than recommended by 

manufacturer; failure to follow this may cause an unsafe 

condition. 

• Do not use battery driver for other than intended use. Not 

suitable for high-risk task area lighting. 

• Equipment should be mounted in locations and 

at heights where it will not readily be subjected to 

tampering by unauthorized personnel.

• Do not mount near gas or electric heaters.

STEP 1: PREPARE FOR INSTALLATION                                

1.  Disconnect Power. AC power must be off before proceeding 

with assembly or installation. Always disconnect power 

during installation or maintenance. Ensure the power is OFF 

and disconnected by turning off the circuit breaker or by 

removing the appropriate fuse at the fuse box.

2. Before installation, ensure the input power is 120-277VAC, 

60Hz and supply wires are rated for at least 90°C (194°F).

3. Review installation diagrams (Figures 1-4).

4. Carefully remove fixture components and parts pack 

included for assembly. Check to ensure all parts are 

included. Account for small parts and destroy packing 

material, as these may be hazardous to children. 

5. Gather required tools.

CAUTION: 

Do not rely on wall switch alone to turn off power. Turning the 

power off to the light switch alone is not sufficient to prevent electrical 

shock.

STEP 2: ELECTRICAL CONNECTIONS                                      

Note: 

Assistance may be required to support fixture during installation.

1. Pull out the supply wires and house grounding wire from the 

junction box.

2.  Open the fixture by loosening the bottom screw (Figure 2). 

This separates the front housing from the back plate. 

Note if installing with BB Model: 

 Remove back plate from Conduit 

Entry Wiring Box, install silicon gasket to groove, then install Wiring Box 

to standard or PE models using screws provided. 

PRODUCT MAINTENANCE                                                          

1. Turn off power to fixture. Be sure fixture temperature is 

cool enough to touch. Do not clean or maintain while fixture is 

energized.

2. Dust fixture with a clean and soft, dry cloth.

3. Wipe fixture clean with a damp cloth as needed. Do not use 

any cleaners with harsh chemicals, solvents, or abrasives. Do 

not use abrasive materials such as scouring pads or powders, 

steel wool or abrasive paper.

4. Allow fixture to dry completely before power is restored.

Note: 

There are no user serviceable parts inside fixture. Do not touch LED’s.

Note for EL Models:

 It is recommended and required by applicable 

code to test battery ballast to ensure proper function of the system. Push 

the test switch for thirty (30) seconds every thirty (30) days to ensure 

the battery driver is functioning by illuminating the light source. Conduct 

a ninety (90) minutes discharge test one (1) time per year; LED light 

source should be illuminated for a minimum of ninety (90) minutes .

LISTINGS: 

UL certified to US and Canadian safety standards; 

Wet location listed (wall mount only).

5-YEAR LIMITED WARRANTY: 

Failure to follow any of these 

instructions could void product warranties. For a complete 

listing of product Terms and Conditions, please visit 

www.acuitybrands.com

. Acuity Brands Lighting, Inc. assumes 

no responsibilities for claims arising out of improper or careless 

installation or handling of its products.

TROUBLESHOOTING GUIDE

Problem:

Corrective Action:

Fixture will not 

illuminate.

1. Verify photocell is working properly by covering 

it to block light from entering (light should turn on) 

(PE Models Only)

.

2. Verify line voltage is correct.
3. Check wiring and connections.
4. Verify power supply is on at switch and 

breaker.
5. Test or replace switch.

Fixture will not 

turn off.

Verify photocell is working properly by shining a 

flashlight into it (light should turn off) 

(PE Models 

Only)

.

Circuit breaker 

trips when 

fixture is 

illuminated.

Check wire connections. Ensure wires are not 

crossed and power wire is not grounding out. 

Consult electrician.

Light flickering 

or light is 

cycling on and 

off.

1. Eliminate reflective surfaces or reposition 

fixture.
2. Check wiring and connections.
3. Test or replace switch.
4. Consult electrician.

If further assistance is required, contact:

Technical Support at: (800) 748-5070