6
V1.0
Operation
The LED Profile 300WW can operate in three different modes. In each mode you can run the fixture as a stand-
alone fixture or in a master/slave configuration. This next section will detail the differences in the operating modes.
Control Menu Map
Default setting in
bold
.
MAIN MENU
LEVEL 1
LEVEL 2
LEVEL 3
FUNCTION INSTRUCTION
DMX
001-512
DMX address setting
Mode
DMX
1/2/3CH
DMX channel mode
Auto
Program
001-008
Preset programs
Speed
001-009
Programs speed
Manual
Brightness
000-255
Dimmer 0-100%
Strobe
000-255
Strobe with speed increasing
Dimmer
Curve
0.3-3.0
Dimmer curves adjustment
Mode
Standard
Dimmer mode, Standard
Stage
Dimmer mode, Stage
TV
Dimmer mode, TV
Architecture
Dimmer mode, Architecture
Theatre
Dimmer mode, Theatre
Studio
Studio power mode, silent
Custom
Fade in
(150 ms~2230 ms)
Custom dimmer curve
Fade out
(150 ms~2230 ms)
Advance
Authorization
On/
Off
Advanced settings/calibration(
Only
qualified technicians should perform
this function. Contact your local dealer
for password.
)
Signal Priority
DMX
DMX signal priority setting
Signal Hold
On
/Off
Run if signal cut
RDM
On
/Off
RDM function on/off
Screen Timeout
30S
Display shut off time
Never
Screen Brightness
25-100%
Display brightness
Dimming Freq
1.20 - 24.0 KHz
Dimmer frequency setting
Reset
Yes/No
System reset
Reverse
Yes/No
Display reverse 180 degree
Addressing
All fixtures should be given a DMX address when using DMX signal, so that the correct fixture responds to the
correct control signal. This digital starting address is the channel number from which t he fixture starts to listen to
the digital control information sent out from the DMX controller. The allocation of this starting address is achieved