3  INSTALL BATTERIES

Main Unit:

 Always install batteries into the main unit first. On the back of the unit, 

remove the battery compartment cover. Insert 2 AA alkaline (or lithium – See NOTES 
below) batteries. Replace the cover.

Wireless Sensor:

 After batteries have been put into the main unit, remove the 4 screws to 

remove the back cover of the wireless sensor. Insert 2 AA alkaline (or lithium) batteries. 
Press the “TX” button and replace the back cover and the 4 screws on the sensor. Put 
the sensor aside for now, and continue to learn about the main unit. Later, in part 5 of 
this manual you’ll learn more about the wireless sensor.

NOTE: 

When replacing the batteries for the wireless sensor, remove the batteries from 

the sensor and clear the sensor’s channel on the main unit by pressing and holding the 
CHANNEL button when the corresponding channel is displayed. Reinstall the batteries 
into the wireless sensor and press and release the TX button to synchronize the units.

 

Low Battery Indicator:

 

 

 

When the battery level is low for the main unit or the wireless sensor, the 

 

low battery level icons will illuminate.

4  CHOOSE WHERE TO PLACE THE MAIN UNIT and WIRELESS SENSOR

 

Main Unit: 

Choose wall mount or table-top placement.

• Choose a location for each unit that is at least 10 feet away from other electronic   
devices that may interfere with the wireless signal.
• Wall mounting: Use the mounting slot on the back of the unit to hang it from one of the 
supplied screws.
• Table-top placement: Fold out the integrated table-top stands to place the main unit
on a table-top surface.

Wireless Sensor:

 When placing the sensor, consider these things:

• Although the sensor is designed for outdoor use, placement in a protected area will 
prolong its life.
• Mounting: Use the mounting slot on the back of the unit to hang it from one of the   
supplied screws.
• The sensor must be within 100 feet (30 meters) of the main unit.
• The sensor is resistant to weather and to water. It is NOT WATERPROOF.
• Prolonged exposure to cold weather may cause damage to the LCD panel.
• Wireless sensor can be placed outdoors to observe outdoor temperatures and
humidity.
• In extremely cold temperatures, it may be necessary to use the included low tempera-
ture adaptor to ensure continued operation. This involves bringing the wireless sensor 
indoors and routing the wired temperature adaptor outside to observe outdoor tempera-
tures. See page 4 for more information.

Main Unit

BACK

Wireless Sensor

BACK

SET

P+

P-

SNOOZE

LITHIUM

BATTERIES

ALKALINE

BATTERIES

-22ºF

158ºF

-4ºF

158ºF

(-30ºC)

(70ºC)

(70ºC)

(-20ºC)

Operating Range of Batteries

Severe cold (below -4º F/-20º C) can cause alkaline 
batteries to freeze and function improperly. Use lithium 
batteries in extremely low temperature conditions to 
ensure continued operation. 

Placement

CHANNEL

MIN/MAX

PRESSURE

ALARM

+  

- C/F

M

O

N

T

U

E

W

E

D

T

H

U

F

R

I

S

A

T

S

U

N

0

-1

-2

-3

-6

-12

-.24 

-.18 

-.12 

-.06 

+.06 

+.12 

+.18 

+.24 

- 8 

- 6 

- 4 

- 2 

+2 

+4 

+6 

+8 

inHg/Hr 

Hr/hPa 

MOON

REMOTE

INDOOR

OUTDOOR

PRESSURE

FORECAST

MAIN UNIT

0

(zone)

RF WIRELESS

AA

AA

REMOVE 4 SCREWS

TO OPEN BATTERY

COMPARTMENT

AA

AA

TX C/F

MODE

1 2 3

AA

AA

Integrated FOLD-OUT stands

Summary of Contents for 00973

Page 1: ...REMOTE INDOOR OUTDOOR PRESSURE FORECAST MAIN UNIT 0 zone 2 READ Please read this entire manual carefully before you set up the instrument and begin to use it In this way you can become familiar with the features of the weather station clock to get the most benefit from it 9 PRODUCT SPECIFICATIONS MODEL 00593W MEASUREMENT RANGE Indoor main unit 0º C to 50º C 32º F to 122º F Outdoor Indoor humidity ...

Page 2: ...crews Table top placement Fold out the integrated table top stands to place the main unit on a table top surface Wireless Sensor When placing the sensor consider these things Although the sensor is designed for outdoor use placement in a protected area will prolong its life Mounting Use the mounting slot on the back of the unit to hang it from one of the supplied screws The sensor must be within 1...

Page 3: ...perature adaptor by running the wire out through a soft seal opening such as a window or door When routing the wire for the low temperature adaptor make certain that the wire will not be severed or damaged WIRELESS SENSOR LOW TEMP ADAPTOR LOW TEMP SENSOR EXTREMELY LOW TEMPERATURES low temp adaptor is used outside to observe temperature Wireless Sensor is protected indoors in extreme temperatures I...

Page 4: ...lock The antenna icon will flash on and off during synchronization If the icon disap pears this indicates that the radio signal is not available If you are unable to obtain a signal after a long period of time try placing the base unit away from sources of interference such as computers televisions cordless phone bases and other electronic items Note The synchronization process can take 24 72 hour...

Page 5: ...it 9 8 Moon Phase The moon phase will automatically display based on the calender date The moon phase display will scroll from left to right and pause for about 5 seconds to display the current moon phase NOTE the moon phase will not be correct unless the date and year are programmed correctly OTHER ADJUSTMENTS Changing the Pressure Units To change the scale between mb milibars hPA hectoPascals an...

Reviews: