Push button
Redundancy Parameters
which is located in the bottom of the page to change
the parameters of your device. You will see the next page:
Supply parameters
— Set the minimum/maximum
parameters for voltage, power or amperage supply and
waveguide switch motor voltage value:
Minimum DC
– set here minimum value for Redundancy
supply. This value:
can’t
be
lower
than
Motor DC
value for proper
Switch work
can’t be lower than minimum permissible working
voltage for BUC or LNB.
Minimum voltage value can’t be lower than 12V;
Maximum DC
– Set the maximum value for redundancy
supply. This value:
can be higher than power supply
Motor DC
(In that
case value will be lowered to needed automatically)
can’t be higher than max. permissible working
voltage for BUC or LNB.
Maximum voltage value can’t be higher than 55V;
Minimum Power/Current
– Set here minimum
Power or Current (depend from the flag in
Watt/Ampere field for each BUC or LNB and must
be lower than minimum power (current) value for
BUC or LNB, but can’t be lower than 0.02 A;
Maximum Power/Current
– Set the maximum Power
or Current for each BUC and LNB. It must be higher
than maximum power (current) value for BUC or LNB,
but can’t be higher than 5 A;
Motor DC
– Set the nominal voltage value that written
in specifications for your switch device
.
REF Mode
— Chose between Autodetect and External
reference frequency.
Watt/Ampere
— Chose what parameter will be shown
in the Minimum/Maximum Power cells.
Redundancy Mode (in development)
— Chose
operation mode for your Redundancy System. Power can be supplied for both BUC’s (
Hot
)
or only for the active one (
Cold
).
Power Supply Priority
— set priority of device power supply. Power Supply Priority function
searching available power supply and use it in the case that supply parameters are in setting
limits. If supply parameters correct, device feeds in accordance to the established priority.
“0” – the highest priority
“2” – the lowest priority
Serial Interface
— set parameters of Redundancy connection with BUC via M&C interface.
Choose port you want to enable and set it parity, speed and bit rare (Bit rate speed depends
on BUC version).