ABD100KX User Manual
Page 8 of 34
INSTALLATION AND OVERVIEW
General Description
This section describes the installation and theory of operation of the block up converter.
ABD100KX is powered by +80~+240 VAC via IF cable or MS connector.
It will amplify an input signal from an L-Band RF source up to a power level of 100 Watts (min) CW in Ku-
Band.
The block up converter can be used as a stand-alone unit or in a redundant configuration.
Specifications
Table 1 summarizes the specifications of the ABD100KX BUC. For mechanical specifications, refer to the
outline drawing, Appendix 1.
General Considerations
The block up converter shall meet all specifications over full bandwidth and under all environmental
conditions when terminated with a load of VSWR at 2:1 unless otherwise specified. All RF specifications
shall be met within five minutes after applying power, except gain flatness, which shall be met after a warm-up
period of ten minutes. During the warm-up period, the block up converter shall not exhibit any alarm or
require an RF mute input signal to reset any alarm/fault latches.
Securing the block up converter
Align the block up converter output waveguide flange with the mating flange of the antenna feeder waveguide.
Using the O-ring and hardware provided, connect the antenna feeder waveguide. Torque the flange screws to
16 inch-pounds (1.8 N-m). Attach the proper cables for waveguide for IF input, AC power and M&C if
equipped to the corresponding connectors of the block up converter.
The cylindrical connectors are labeled clearly and have different pin layouts. It is impossible
to incorrectly install the mating connectors.