ABD100KX User Manual
Page 12 of 34
Connections and Mounting Hardware
The IF input connection requires a coaxial cable with an F or N type connector. The RF output requires a
waveguide with a WR-75G flat flange. An O-ring shall be used to seal the waveguide connection.
Assembly and Installation
Use the information in this section as a guide to assemble and install the block up converter. The specified
humidity is up to 100% during operation. However, installation should be carried out in dry conditions, free of
salt spray or excessive humidity. This will eliminate the possibility of moisture and other foreign substances
from entering the output waveguide flange.
CAUTION!!
Only authorized technical personnel should perform the Installation and
proper electrical hookups of the block up converter.
The block up converter is designed to operate in an outdoor environment and is waterproof when mounted in
the correct orientation. To provide a sufficient airflow, the block up converter should be mounted with a
minimum clearance of 3 inches on all four sides and the bottom. Adequate cooling for the block up converter
will provide years of top performance.