Actox ABD100KX User Manual Download Page 21

ABD100KX User Manual  

 

 

Page 21 of 34 

50.5dB.)  

 

 

 

 

 

1) cmd: 7E FF 02 18 FE E4 
7F  

 

 

 

 

 

reply: 7E FF 84 18 FE 00 C8 
AA 7F  

Get 
Attenuation 

 

7E FF 02 
18 FE E4 
7F  

Query device for 
current attenuation  

Update Attenuation: 

7E FF 84 18 FE GG 
GG ZZ 7F  

AA AA = Attenuation in 10 
x dB. ZZ = CRC.  

(Atten = 0x00C8 = 0d200 = 
20.0dB.) 2) cmd: 7E FF 02 
18 FE E4 7F  

 

 

 

 

 

reply: 7E FF 84 18 FE 00 69 
0B 7F  

 

 

 

 

 

(Atten = 0x0069 = 0d105 = 
10.5dB.)  

Get Low 
Power Alarm 
Threshold 

 

7E FF 02 
10 10 02 
7F  

Query device for 
current low power 
alarm threshold  

Update Low Power  
Alarm Threshold: 

7E FF 84 10 10 TT 
TT ZZ 7F  

TT TT = low power 
threshold in 10 x dBm. ZZ = 
CRC. Note: zero value 
means low power alarm 
disabled  

1) cmd: 7E FF 02 10 10 02 
7F reply: 7E FF 84 10 10 01 
AE 2B 7F (Thresh = 
0x01AE = 0d470 = 
47.0dBm.) 2) cmd: 7E FF 02 
10 10 02 7F reply: 7E FF 84 
10 10 00 00 84 7F (Thresh = 
0x0000 = 0d00 = alarm is 
disabled.)  

 

 

 

 

 

1) cmd: 7E FF 02 06 10 14 
7F  

 

 

 

 

 

reply: 7E FF 84 06 10 01 2C 
BF 7F  

Get Power 
Supply 
Voltage 

 

7E FF 02 
06 10 14 
7F  

Query device for 
power supply voltage  

Update PS Voltage: 

7E FF 84 17 FF PP 
PP ZZ 7F  

VV VV = PS voltage in 10 x 
V. ZZ = CRC.  

(Power = 0x0064 = 0d100 = 
10.0V.) 2) cmd: 7E FF 02 06 
10 14 7F  

 

 

 

 

 

reply: 7E FF 84 06 10 00 63 
F1 7F  

 

 

 

 

 

(Power = 0x0063 = 0d99 = 
9.9V.)  

 

 

 

Command 

 

Packet 
format 

 

Explanation 

 

Possible replies 

 

Interpretation 

 

Examples 

 

Get Power 
Supply 
Current 

 

7E FF 02 
06 11 15 
7F  

Query device for 
power supply 
current  

Update PS Current : 

7E FF 84 06 11 PP PP 
ZZ 7F  

CC CC = PS current in 
10 x A. ZZ = CRC.  

1) cmd: 7E FF 02 06 11 15 7F reply: 
7E FF 84 06 11 00 AD 3E 7F 
(Power = 0x00AD = 0d173 = 
17.3A.) 2) cmd: 7E FF 02 06 11 15 
7F reply: 7E FF 84 06 11 00 97 04 
7F (Power = 0x0097 = 0d151 = 
15.1A.)  

Get Mute 
Status 

 

7E FF 02 
06 01 05 
7F  

Query device for 
mute status  

Update Mute Status: 

7E FF 84 06 01 00 MM 
ZZ 7F  

MM = Mute status (0 = 
enabled; 1 = muted). 
ZZ = CRC.  

1) cmd: 7E FF 02 06 01 05 7F reply: 
7E FF 84 06 01 00 00 83 7F (Device 
is enabled.) 2) cmd: 7E FF 02 06 01 
05 7F reply: 7E FF 84 06 01 00 01 
82 7F (Device is muted.)  

Get  Device 
Address 

 

7E FF 02 
03 04 05 
7F  

Query  for device 
address  

Update device 
address: 

7E FF 84 03 

04 00 XX ZZ 7F  

XX = Device address. 
ZZ = CRC.  

1) cmd: 7E FF 02 03 04 05 7F reply: 
7E FF 84 03 04 00 0A 89 7F 
(Device address = 0xA) 2) cmd: 7E 
FF 02 03 04 05 7F reply: 7E FF 84 
03 04 00 0E 8D 7F (Device address 
= 0xE)  

Get Over 
Temperature 
Alarm 

 

7E FF 02 
00 02 00 
7F  

Query device for 
over temperature 
alarm  

Update over 
temperature alarm: 

7E FF 84 00 02 00 XX 
ZZ 7F  

XX = Alarm state (0 = 
no alarm; 1= alarm). 
ZZ = CRC.  

1) cmd: 7E FF 02 00 02 00 7F reply: 
7E FF 84 00 02 00 01 87 7F (Over 
temp alarm is raised) 2) cmd: 7E FF 
02 00 02 00 7F reply: 7E FF 84 00 
02 00 00 86 7F (Over temp alarm is 
clear)  

Summary of Contents for ABD100KX

Page 1: ...ABD100KX User Manual Page 1 of 34 ABD100KX ABD100KXF 100 W Extended Ku Band BUC USER MANUAL...

Page 2: ...description 8 Considerations Securing the Block Up Converter Installing the Block Up Converter 9 LED Indicators Connector Pin Assignment 10MHz Reference Powering Options Setting L O Setting Tx Rx Freq...

Page 3: ...rocedure Block Up Converter Cooling System Preventive Maintenance Performance Check Troubleshooting Out of Warranty Repair Appendix 1 Technical Specifications 17 Appendix 2 Mechanical Drawing 18 Appen...

Page 4: ...tion and maintenance of the ABD100KX BUC It contains information intended for engineers technicians and operators working with the block up converter To make inquiries or to report errors of fact or o...

Page 5: ...cterized by unparalleled durability and dependability This is the smallest and lightest 100W L To Ku Band Block Up Converter and is designed to be mounted on the feed horn The unit is ideal for portab...

Page 6: ...roper packaging please notify Actox Corporation immediately Equipment Damage or Loss Actox Corporation is not responsible for damage or loss of equipment during transit For further information contact...

Page 7: ...others The block up converter must be installed in accordance with the conditions and recommendations contained in the following sections Safety Precautions Carelessness or mishandling of the block u...

Page 8: ...n terminated with a load of VSWR at 2 1 unless otherwise specified All RF specifications shall be met within five minutes after applying power except gain flatness which shall be met after a warm up p...

Page 9: ...antenna to the satellite Lightning arrestors should be used at the site to protect personnel and equipment Preparation Mounting Considerations Optional Mounting Brackets are available that will facili...

Page 10: ...t 10MHz LED Green Blinking Internal 10MHz Reference 10MHz Reference The BUC must receive a stable external 10MHz reference provided by a stable signal source such as a signal generator satellite modem...

Page 11: ...h calibrated insertion loss up to 15GHz 40 dB attenuator High Power to match HPA output Assortment of cables connectors and adapters calibrated up to 18 GHz Ensure that the BUC TX output power is disa...

Page 12: ...ried out in dry conditions free of salt spray or excessive humidity This will eliminate the possibility of moisture and other foreign substances from entering the output waveguide flange CAUTION Only...

Page 13: ...of the RF Amplifier provide the necessary gain and low insertion loss The amplified signal is transmitted through the output waveguide section to a satellite up link system Monitor and Control option...

Page 14: ...ill result in personal injury Safe and careful installation of this block up converter will eliminate the possibility of accidents and provide years of top performance Verify the antenna feed waveguid...

Page 15: ...Failure to observe this precaution may result in personal injury or death This includes the removal of any RF power originating from other system components When the block up converter is in the hot s...

Page 16: ...From the output power measurements determine rated output power Record value on a test data sheet Measure the Two tone Inter modulation Suppression using two equal signals separated by 5 MHz Record va...

Page 17: ...able frequency 10 MHz sine wave input power 5 to 5 dBm input port Phase noise Exceeds Intelsat s standard IESS308 309 55 dBc Hz max 10 Hz 65 dBc Hz max 100 Hz 75 dBc Hz max 1 KHz 85 dBc Hz max 10 KHz...

Page 18: ...ABD100KX User Manual Page 18 of 34 Appendix 2 Mechanical Drawing...

Page 19: ...be sent via email to the following address Fax 1 866 888 6087 Email mark_moore actox com For additional information please contact our customer service department at 619 906 8893 or 1 866 888 6087 Act...

Page 20: ...T TT ZZ 7F TT TT Device temp in C 273 ZZ CRC Temp 0x0102 0d258 273 15 C 2 cmd 7E FF 02 06 06 02 7F reply 7E FF 84 06 06 01 34 B1 7F Temp 0x0134 0d308 273 35 C Get Power Supply Temperature 7E FF 02 06...

Page 21: ...format Explanation Possible replies Interpretation Examples Get Power Supply Current 7E FF 02 06 11 15 7F Query device for power supply current Update PS Current 7E FF 84 06 11 PP PP ZZ 7F CC CC PS c...

Page 22: ...0d105 0x0069 Set Low Power Alarm Threshold 7E FF 14 10 10 TT TT ZZ 7F Set low power alarm threshold Note zero value means low power alarm disabled ACK NACK TT TT Low power threshold in 10 x dBm ZZ CRC...

Page 23: ...se element ACK command high nibble 0xE Acknowledge a received packet NACK command high nibble 0xF Reject a received packet Not ACKnowledge Data1 Datan contains the packet payload The value of the data...

Page 24: ...database element 0x0606 from the Booster device address 0x0F the command is Example Only 7E FF 02 06 06 02 7F Dest Src 0xFF CMD Len 0x02 1111 1111 0000 0010 XOR 1111 1101 Data1 0x06 0000 0110 XOR 1111...

Page 25: ...carried by cable with 19 pin female connector fig 1 on the one side and RJ45 fig 2 two DB9 fig 3 female connectors RS232 and RS485 on the other side Figure 1 1 19 pin connector configuration Figure 1...

Page 26: ...NC U NC NC K Ethernet 3 RX_P C 6 RX_N P 1 TX_P L 2 TX_N N RS 485 5 GNDISO A 4 TX_B H 3 TX_A T 1 RX_B F 2 RX_A S RS 232 5 GNDISO G 2 TX_RS 232 J 3 RX_RS 232 E NC MUTE_IN M NC ALARM_IN B NC P_OUT_OUT D...

Page 27: ...rial Number Read only Factory set Each unit has a unique number Below the head you can find two tabs Monitor and Settings Monitor Tab Tab Monitor provides online telemetry of BUC Output Power Display...

Page 28: ...nge according to the established L O o Green color frequency 26550Hz o Blinking green color frequency 27400Hz o Yellow color frequency 28050Hz o Blinking yellow color 29050HZ SSPA indicates Solid Stat...

Page 29: ...ess Configurable Factory default 192 168 1 250 Default Gateway Configurable Factory default 192 168 1 1 Port Configurable Factory default 80 Subnet Mask Configurable Factory default 255 255 255 0 MAC...

Page 30: ...utton Changes button functions o Led sw switch on off LED s on dashboard o Ref sw switch on off auto detect function if BUC works on internal reference frequency Configurable Factory default Ref sw Fi...

Page 31: ...and password in appropriate fields There are two access levels User and Admin By default User s access level ID Login User Password 1234 Admin s access level ID Login Admin Password 1234 When you ente...

Page 32: ...to UNMUTE click button Switch 10MHZ to change mode from INTERNAL to EXTERNAL click button Switch L O choose right Local Oscillation frequency and click button Set to apply changes Attenuation for cha...

Page 33: ...d for RS232 and RS485 ports and BUC address Right panel designed to change login configurations such as Name and Password Figure 3 5 Settings Panel Access Level Admin Admin Access level gives wider ra...

Page 34: ...his password you wouldn t get access to BUC via SNMP browser Type new password in the green field In field Confirm New Community repeat this password and push button Save to save password Device Name...