READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION.
MODEL F170A
The Aberdeen Bldg.
14841 Dallas Parkway, Suite 500
Dallas, TX 75254
Page 1: ...1 READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION MODEL F170A The Aberdeen Bldg 14841 Dallas Parkway Suite 500 Dallas TX 75254...
Page 2: ...eep cord away from heated surfaces Do not unplug by pulling on cord to unplug grasp the plug to remove not the cord Never handle plug or device with wet hands Keep hair loose clothing fingers and all...
Page 3: ...vice Specifications 6 Operation 6 Treatment Space 7 Settings 8 General Maintenance Instructions 8 Cleaning Disinfecting and Filter Replacement Instructions 9 ActivePure Cell Replacement Instructions 1...
Page 4: ...cuit board which controls the device operations and an internal fan to draw air through the device as shown in the general device design Figure 1 Lab test results demonstrated the ActivePure Medical G...
Page 5: ...atively charged particles which flow out from a series of carbon brushes Carbon to remove odors Hydrophobic polypropylene pleated media filter designed to reduce airborne contaminants Powerful UVGI bu...
Page 6: ...h 300 CFM 509 m3 h OPERATION DEVICE SPECIFICATIONS Place the ActivePure Medical Guardian in a location that allows air to move freely into around and out of the unit Allow minimum of 12 of clearance a...
Page 7: ...e Movement of people or equipment within the space Rates of ventilation The device is intended to result in a 4 6 log reduction of airborne microorganisms from initial concentrations in 60 minutes as...
Page 8: ...r of the cabinet with a clean soft cloth as needed to remove finger prints smudges etc Clean and disinfect device after each filter change as detailed in the Cleaning Disinfecting and Filter Replaceme...
Page 9: ...hazard sticker 1 plastic bag seal 1 printed copy of instruction for use cleaning disinfecting filter replacement sheet Step 4 Before removing and handling the used filter put on the disposable mask an...
Page 10: ...of the device If soil is heavy or is still visible repeat step with a new CaviWipe until soil is no longer visible Step 15 Allow the device to dry no visible wetting remains No rinsing is required Wi...
Page 11: ...at is used for the reduction of staphylococcus epidermidis and erwinia herbicola bacteria MS2 and Phi X174 viruses and aspergillum niger fungal spores and bacillus globigii bacterial spores from the a...
Page 12: ...des longer fan life Q Why doesn t the display dim immediately when the room gets dark A The automatic dim feature has a brief delay to prevent unnecessary dimming if a shadow momentarily passes in fro...
Page 13: ...use ActivePure Medical s trademarked names images and logos as well as Internet auction sites e g ebay and Craigslist The only approved Internet presence for ActivePure Medical LLC products is www act...
Page 14: ...61000 4 11 This device conforms fully to the EMC requirement of IEC 60601 1 2 and is suitable for use in a professional healthcare environment This device is not effected by RFID wireless networks 2...
Page 15: ...15...
Page 16: ...vePure Medical LLC The Aberdeen Bldg 14841 Dallas Parkway Suite 500 Dallas TX 75254 1 800 572 0317 ActivePure Medical LLC Canada Inc 3480 Laird Road Suite 2 5 Mississauga ON L5L 5Y4 For information re...