www.acti.com
TCM-7411 Hardware User’s Manual
10
This camera provides:
•
1 transistor output
- For connecting external devices such as relays and LEDs. Connected
devices can be activated by Output buttons on the Live View page or through video management
software.
•
1 Digital Input
- An alarm input for connecting devices that can toggle between an open and
closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. The device will
detect the change in digital input and transmit the signal to video surveillance servers.
Terminal Pin Define is described as below:
Pin Name
Description
Spec
DIO PW
Electrically connected in parallel with the con-
nector for the power supply, this pin provides an
auxiliary connector for mains power to the unit.
This pin can also be used to power auxiliary
equipment, with a maximum current of 100mA.
Voltage: 12V DC,
Max: 1.2W
DIO GND
Ground
DO
(Transistor
Output)
Uses an open-collector NPN transistor with the
emitter connected to the GND pin. If used with an
external relay, a diode must be connected in
parallel with the load, for protection against
transient voltages.
Max load = <100mA
Max voltage = 24V
DC (to the
transistor)
DI
(Digital
Input)
Connect to GND to activate, or leave floating (or
unconnected) to deactivate.
Must not be
exposed to
voltages greater
than 30V DC.
Summary of Contents for TCM-7011
Page 15: ...www acti com TCM 7411 Hardware User s Manual 15 Mount the IP Outdoor Fixed Dome Surface...
Page 16: ...www acti com TCM 7411 Hardware User s Manual 16 Mount the IP Outdoor Fixed Dome Flush...
Page 17: ...www acti com TCM 7411 Hardware User s Manual 17 Mount the IP Indoor Fixed Dome Wall...
Page 24: ...www acti com TCM 7411 Hardware User s Manual 24...