background image

www.acti.com

Installation Guide 

 

                 

 

Physical Description 

The Device 

 

 

Front Panel 

Below are the detailed descriptions of the front panel indicators and keypad. 

 

 

 

 

Press to enter SETUP mode 

 

In SETUP menu, press to go 
back a previous screen. 

 

ESC / Quit 

Press to “Enter” or select 
 

Summary of Contents for R12CP-30

Page 1: ...Reader Controller Installation Guide R12CP 30 2019 01 15 ...

Page 2: ...ors 8 Installation Procedure 10 Step 1 Install the Mounting Plate 10 Mounting Directly on the Surface 10 Embedding into the Wall 10 Step 2 Do the Wiring 11 Step 3 Install the Device 12 Step 4 Connect to Power Source 12 Wiring Diagram 13 Connect to Door Contact 13 Connect to Electric Bolt 13 Connect to Magnetic Lock 14 Connect to Reader 14 Connect to Electric Strike 15 Connect to Relay Output Modul...

Page 3: ...ck Setup 17 Enter Setup Mode 17 Initial Setup 17 Change the Language 17 Configure the IP Address 17 Useful Shortcuts 18 How to Exit the Menu 18 How to Change the Master Code 18 How to Lock and Unlock the Keypad 18 Accessing the Device 19 Web Interface 19 ...

Page 4: ...t attempt to service this video device yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Trademarks All names used in this manual are probably registered trademarks of respective companies Liability Every reasonable care has been taken during the writing of this manual Please inform your local office if yo...

Page 5: ...o qualified service personnel under the following conditions 1 When the power supply cord or plug is damaged 2 If liquid has been spilled or objects have fallen into the product 3 If the inner parts of product have been directly exposed to rain or water 4 If the product does not operate normally by following the operating Instructions in this manual Adjust only those controls that are covered by t...

Page 6: ...inal Cables x 5 4 Terminal block strip x 3 5 Screw Pack 6 Waterproof Rubber Strip NOTE Actual items may slightly vary Additional Requirement for Installation The following items are not included in the package Installers must prepare these items to do the installation 1 DC 10 24V Power adapter 2 Ethernet cable 3 Allen wrench ...

Page 7: ... 7 Physical Description The Device Front Panel Below are the detailed descriptions of the front panel indicators and keypad Press to enter SETUP mode In SETUP menu press to go back a previous screen ESC Quit Press to Enter or select ...

Page 8: ...www acti com Installation Guide 8 Connectors This section shows the connectors at the back of the device and its pin mapping definition For wiring examples see Wiring Diagram on page 13 ...

Page 9: ...www acti com Installation Guide 9 ...

Page 10: ... the wall using the mounting plate as template 2 Mark or drill the screw holes if necessary 3 Install the mounting plate by securing four 4 screws as marked on the illustration Embedding into the Wall The device can be flushed or embedded into the wall so only the edge of the mounting plate and the device front panel can be seen on the surface 1 Drill a hole with dimensions of 128 mm x 108 mm This...

Page 11: ...4 for power adapter and lock relay etc CN5 for wiegand connections are commonly used 2 Route the cables such as the power source and other devices such as door lock sensor etc that will be connected to the reader controller through the hole on the wall and the mounting plate 3 Then connect the devices to the supplied terminal block Below is an example of connecting a DC 12V power adapter Note that...

Page 12: ...ng connectors on the reader controller Step 3 Install the Device Align the top part of the reader controller to the mounting plate and attach the two 2 supplied screws Step 4 Connect to Power Source When the unit is connected to the power source the unit will initialize Once complete the LCD will display Ready ...

Page 13: ...www acti com Installation Guide 13 Wiring Diagram This section shows the wiring options you can do with the reader controller Connect to Door Contact Connect to Electric Bolt ...

Page 14: ...www acti com Installation Guide 14 Connect to Magnetic Lock Connect to Reader ...

Page 15: ...www acti com Installation Guide 15 Connect to Electric Strike Connect to Relay Output Module for Added Security ...

Page 16: ... com Installation Guide 16 Wiegand Mode It is possible to use the unit as a reader and connect it to another unit which can be the controller To do this connect the units by Wiegand Below is the wiring diagram ...

Page 17: ... IP Address The default IP address of the device is 192 168 0 100 You can modify the static IP address or enable DHCP mode to obtain automatically obtain an IP address if it is connected to a DHCP server Modify the IP Address To modify the static IP address do the following 1 Press 1 2 3 4 5 6 2 Press 3 Parameters 1 1 Node ID 3 Press four 4 times to scroll through the submenu option until you see ...

Page 18: ...he following 1 Press 1 2 3 4 5 6 2 Press 3 Parameters 1 1 Node ID 3 Press four 4 times to scroll through the submenu option until you see ENABLE DHCP on the screen This screen also shows the current IP address of the device 4 Press 2 to exit the submenu then press repeatedly to go back the previous submenu screens 5 Press 6 to Quit or close the menu Useful Shortcuts How to Exit the Menu Press repe...

Page 19: ...f the IP address is different from each other The default IP address is 192 168 0 100 If the device is connected to a DHCP server then you have to check what the device IP address is in order to type it on the PC web browser See How to Check the IP Address on page 18 to identify the IP address of the device 1 Open a web browser and type the IP address on the address bar 2 If prompted to login type...

Page 20: ...Copyright 2019 ACTi Corporation All Rights Reserved 7F No 1 Alley 20 Lane 407 Sec 2 Ti Ding Blvd Neihu District Taipei Taiwan 114 R O C TEL 886 2 2656 2588 FAX 886 2 2656 2599 Email sales acti com ...

Reviews: