39
Troubleshooting
A5LCY_(i)
Unit Running Parameter
Parameter
Number
Parameter Description
Unit/ range
00
Compressor Actual Rotation
r/s
01
Compressor Target Rotation
r/s
02
DC Bus Voltage
VDC
03
Total Current (÷10)
A
04
Outdoor Air Temperature
°C
05
Outdoor Heat Exchanger Temperature
°C
06
Compressor Discharge Temperature
°C
07
Outdoor Heatsink Temperature
°C
08
Indoor Air Temperature
°C
09
Indoor Heat exchanger Temperature
°C
10
EXV Opening
Pulse
11
Outdoor fan speed
W0 ~ W6
12
Horse power
15: 1.5hp
13
Software version (Production)
14
Software version (Development)
15
3 minutes count up stop timer
16
Communication stage
0~3
17
Indoor On/Off
0- Off, 1-ON
18
Delta D
19
Running mode
0-Fan, 1- Heat, 2-Cool
20
Startup up timer
21
Comp initial control
fl
ag ok
22
Fuzzy control Delta H
23
Comp freq set pointer
24
Comp stop pointer
25
Comp limit pointer
26
Comp limit speed
Max r/s
27
Discharge high temp zone
0-Normal, Other-Active
28
High pressure zone
0-Normal, Other-Active
29
Current control zone
0-Normal, Other-Active
30
Oil return status
0-Normal, Other-Active
31
De-ice setting
0-Normal, Other-Active
32
Dew drop setting
0-Normal, Other-Active
33
Heatsink protection zone
0-Normal, Other-Active
34
Turbo setting
0-Normal, Other-Active
35
Silent setting
0-Normal, Other-Active
36
Low ambient zone
0-Normal, Other-Active
37
Defrost status
0-Normal, Other-Active
38
Pump down status
0-Normal, Other-Active
39
O/D capacity
fl
ag
0- Comp off, 1- Comp On
40
O/D output capacity
In %
41
Target discharge temp
42
EXV control status
0-Initial , 1- Feedback
43
Indoor fan tap
Summary of Contents for A5CCY-C Series
Page 1: ...Inverter Y Single Split Series I A5LCY_ i A5LCY 10DR A5LCY 15DR A5LCY 20CR A5LCY 25CR Models...
Page 2: ......
Page 25: ...22 A5LCY_ i Wiring Diagram Outdoor Unit Indoor Unit Model A5LCY 20 25CR Model A5WMY 20 25JR...
Page 59: ...A5LCY_ i Sound Data Part Number 000353103N2525 A5CKY 25ER...
Page 65: ...Sound Data A5LCY_ i Part Number 000353103M2525 A5CMY 25ER...