34
A5LCY_(i)
Troubleshooting
Error Code Diagnosis by Wireless Handset GS02
SWING
TURBO
QUIET
SLEEP
ON
CANCEL
CANCEL
OFF
TIMER
CLOCK
MODE
FAN
TIMER ON
TIMER OFF
Diagnosis Step
1. Hold down ON TIMER CANCEL button or OFF TIMER CANCEL button for 5 seconds, a “
” indication
fl
ashes on the temperature display section.
2. Press ON TIMER CANCEL or OFF TIMER CANCEL repeatedly until indoor buzzer produces a long beep.
This indicates the error code, refers to Error Codes table and is displayed on the temperature display
section.
3. A short beep or two consecutive beeps indicate non-corresponding error codes.
4. To cancel the error code display, hold down ON TIMER CANCEL or OFF TIMER CANCEL button for 5
seconds. Alternatively, the code display will cancel itself if the button is not pressed for 1 minute.
Error Code Diagnosis by Unit Last State Memory Using Wireless Handset
1. Remove battery from wireless handset.
2. Wait for the display to
fi
nally go off (as this handset uses very small amount of power, hence it takes
longer for the memory to reset).
3. Replace battery again and immediately (before display comes back on the LCD screen), press on Mode
and ON/OFF buttons together until you see “00” is being displayed.
4. Press Mode button to 5:00.
5. Press ON/OFF button once.
6. After that, remove battery from wireless handset and wait until the display has gone off. Then, replace
battery again into the handset.
7. Finally, repeat the fault diagnosis steps by wireless handset GS02 above.
Summary of Contents for A5CCY-C Series
Page 1: ...Inverter Y Single Split Series I A5LCY_ i A5LCY 10DR A5LCY 15DR A5LCY 20CR A5LCY 25CR Models...
Page 2: ......
Page 25: ...22 A5LCY_ i Wiring Diagram Outdoor Unit Indoor Unit Model A5LCY 20 25CR Model A5WMY 20 25JR...
Page 59: ...A5LCY_ i Sound Data Part Number 000353103N2525 A5CKY 25ER...
Page 65: ...Sound Data A5LCY_ i Part Number 000353103M2525 A5CMY 25ER...