ACS GSM-3000 Technical Manual Download Page 15

GSM-3000

  

ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | D- 84307 Eggenfelden | www.acs-controlsystem.de | 

[email protected]

  

 

     | 15 |

 

9.

 

Technical data 

Auxiliary power supply 

 

Supply voltage: 

Integrated lithium battery, 3,6V / 19Ah / style D 

 

Battery run time: 

 3.000 SMS / 400 data transmissions / 400 hours standby, 

 

depending on settings and environmental conditions 

 

The using of another than the specified battery the run time can 

 

differ considerably from these specifications 

 

Communication GSM/GPRS 

 

Transmit frequency: 

Quad band 900 / 1800 MHz resp. 950 / 1900 MHz, EGSM/GPRS 

 

Transmit power: 

Class 4 (2 W) at 900/950 MHz / class 1 (1W) at 1800/1900 MHz 

 

Transmission rate: 

9600 Baud, nontransparent 

 

SIM card: 

Support of 1,8V resp. 3V 

 SIM cards, activated for data transfer 

 

Interface – PC 

 

Type: 

RS485 - full-duplex 

 

Transmission rate: 

9600 Baud 

 

Interface – Water level sensor 

 

Type: 

RS485 - full-duplex 

 

Transmission rate: 

9600 Baud 

 

Clock 

 

Type: 

Real time clock 

 

Cycle accuracy: 

1 minute / month 

 

Materials 

 

Filler cap:   

 

 

 

 

 

 

Aluminum, powder coated 

 

Module housing: 

POM 

 polyoxymethylene (Delrin

 

PC 

 polycarbonate (Makrolon

 

Aluminum 

 

Interface plug / socket: 

Socket brass nickel plated / chrome plated, insert PBT/PUR,  

 

contacts gold plated 

 

Interface cable: 

PE 

 polyethylene 

 

Gaskets: 

Silicone 

 

Environmental conditions

 

 

Environmental temperature: 

 20°C...+60°C 

 

Weight: 

1,1 kg (with filler cap 

G 4“)

 

 

1,8 kg (with filler cap 

G 4 ½“)

 

 

1,5 kg (with filler cap 

G 5“)

 

 

1,7 kg (with filler cap 

G 6“)

 

 

Protection classification: 

IP68 up to 3 mWs 

EN/IEC 60529 

 

Climatic classification: 

4K4H 

 

 

 

EN/IEC 60721-3-4 

 

Shock classification:  

15 g 

 

 

 

EN/IEC 60068-2-27    (11 ms) 

 

Vibration classification:  

5 g 

 

 

 

EN/IEC 60068-2-6    (10 - 2000 Hz) 

 

EM 

 compatibility: 

EN 301 489 -1 / -7 / DIN EN 55022 / DIN EN 61000-4-2 / -4-3 / -4-5 

 

Reference conditions:

 

EN/IEC 60770-1 resp. EN/IEC 61003-1 
T = 25 °C, rel. humidity 45...75 %, environm. air pressure 860...1060 kPa

 

 

Summary of Contents for GSM-3000

Page 1: ...y GPRS to FTP server Quad band compatible for the worldwide use in mobile telephony network Remote alarming to PC or mobile phone Integrated battery for run times of more than 5 years Connection of wa...

Page 2: ...the office resp the operation forces in the case of alarming Dependent on the configuration of the RDT module different functions are possible These are e g the transmission of alarming messages per...

Page 3: ...ng of mobile phones is not allowed e g in hospitals or explosive hazardous areas Electromagnetically sensitive devices can be interfered in their operation because of the high energetic radio waves at...

Page 4: ...e carried out by the RDT module This is not possible with an unloaded prepaid SIM card For using of SIM card the input of the correct PIN code by using the operation software is necessary Without thes...

Page 5: ...t at removed plug the protection cap must be fully inserted into the socket Connecting a sensor For a complete measuring system with RDT the connection of a water level sensor to the RDT module is nec...

Page 6: ...r 20 cycles After opening the filler cap the RDT module requests at first all relevant data s from the connected water level sensor Getting Data Please wait Name Donau 1 Measure Value 3 459 mwc Batter...

Page 7: ...t By setting a daily standby time of 2 minutes every day at 8 00 o clock the RDT module log on every day at 8 00 o clock to the GSM network at the respective provider and checks if new SMS messages ar...

Page 8: ...resp FTP resp SNTP 0 PC resp FTP data transmission resp internet time synchronization off no state SMS 1 PC resp FTP data transmission resp internet time synchronization on send state SMS The respons...

Page 9: ...irmed Example 4 The password of the RDT module is 123456789 The module should be set to an enforced standby mode for 2 hours 120 minutes The state SMS should be sent SMS message 123456789 SFSB 120 CSS...

Page 10: ...y alarm GSBP get standby prealarm GGPW get RDT module password GHPW get water level sensor password GST1 get status text 1 GST2 get status text 2 GLBT get low battery text GUPOT get upper prealarm ove...

Page 11: ...N8 set 8th telephone number SASI set alarm SMS interval in minutes STNS1 set telephone number status 1 STNS2 set telephone number status 2 STNSC set telephone number service center STNP1 set 1st telep...

Page 12: ...TP server address SFTPU set FTP server user name SFTPP set FTP server password SFTPD set FTP server directory SFAI set FTP alarm interval in minutes SCDF set CSV date format SCTF set CSV time format S...

Page 13: ...remaining battery capacity lower than 30 in order to guarantee always a sufficient safety function After a battery change the battery counter must be reset by using the operation software in order to...

Page 14: ...tion The chemical and physical characteristics of the product A short description of the occurred error Before returning the device for repair the following measures must be proceeded All stick produc...

Page 15: ...00 Baud Interface Water level sensor Type RS485 full duplex Transmission rate 9600 Baud Clock Type Real time clock Cycle accuracy 1 minute month Materials Filler cap Aluminum powder coated Module hous...

Page 16: ...GSM 3000 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem de info acs controlsystem de 16 10 Dimension drawings...

Page 17: ...ter level tube 4 ISO 228 1 DIN 259 412 Filler cap for installation on water level tube G 4 ISO 228 1 DIN 259 500 Filler cap for installation on water level tube G 5 ISO 228 1 DIN 259 600 Filler cap fo...

Page 18: ...GSM 3000 ACS CONTROL SYSTEM GmbH Lauterbachstr 57 D 84307 Eggenfelden www acs controlsystem de info acs controlsystem de 18...

Reviews: