GSM-3000
ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57 | D- 84307 Eggenfelden | www.acs-controlsystem.de |
| 11 |
Listing
–
get commands
GFTPS
get FTP server address
GFTPU
get FTP server user name
GFTPP
get FTP server password
GFTPD
get FTP server directory
GFAI
get FTP alarm interval in minutes
GFTPFAIC get FTP forced alarm interval counter (FTP on if > 0)
for forced FTP transmission without alarm condition
GCDF
get CSV date format
GCTF
get CSV time format
GCSC
get CSV separator
GLCDA
get LCD active
GNTPO get network time protocol offset in minutes
GNTPS get network time protocol server
GFLM
get forced log book mode transmit to ftp server
GSOA
get sensor operation active (0=stop / 1=start)
GOPT get options (bit-array)
bit1 >> internet time synchronization for sensor
Listing
–
set commands
SMI
set measure interval in minutes
SBCAP
set battery capacity
SBWP
set battery warning percentage
STN1
set 1st telephone number
STN2
set 2nd telephone number
STN3
set 3rd telephone number
STN4
set 4th telephone number
STN5
set 5th telephone number
STN6
set 6th telephone number
STN7
set 7th telephone number
STN8
set 8th telephone number
SASI
set alarm SMS interval in minutes
STNS1
set telephone number status 1
STNS2
set telephone number status 2
STNSC
set telephone number service center
STNP1
set 1st telephone number GSM data transfer to PC
STNP2
set 2nd telephone number GSM data transfer to PC
SCLK
set clock
SSB1
set 1st standby
SSB2
set 2nd standby
SSB3
set 3rd standby
SSB4
set 4th standby
SFSB
set forced standby
SSBA
set standby alarm
SSBP
set standby prealarm
SGPW
set RDT module password
SHPW
set water level sensor password
SST1
set status text 1
SST2
set status text 2
SLBT
set low battery text
SUPOT
set upper prealarm overrun text
SUPUT
set upper prealarm underrun text
SUAOT
set upper alarm overrun text
SUAUT
set upper alarm underrun text
SLPUT
set lower prealarm underrun text
SLPOT
set lower prealarm overrun text
SLAOT
set lower alarm overrun text
SLAUT
set lower alarm underrun text
SAMIH
set alarm measuring interval high
SAMIL
set alarm measuring interval low
SAFH
set alarm filter high
SAFL
set alarm filter low
SALH
set alarm limit high
SALL
set alarm limit low
SAHH
set alarm hysteresis high
SAHL
set alarm hysteresis low
SALHT
set alarm limit high temperature
SALLT
set alarm limit low temperature
SAHHT
set alarm hysteresis high temperature
SAHLT
set alarm hysteresis low temperature