background image

 
 

 

Access Control System 

 
 
 
 
 
 

EXP-06E 

Single Door Access Controller 

Installation and Operation 

Instructions

 

 
 
 
 
 
 
 
 
 
 
 

Version 6.6 

Revision 2003-5 

Summary of Contents for EXP-06E

Page 1: ...Access Control System EXP 06E Single Door Access Controller Installation and Operation Instructions Version 6 6 Revision 2003 5...

Page 2: ...t sensors such as intrusion motion detectors door contacts low temperature and can activate cameras or lighting controls automatically unattended The ACS access Control System provides user with much...

Page 3: ...rsion Motherboard 1 x RS232 port Display SVGA 800x600 resolution color monitor with 16 bits color Input Device Enhanced 101 keyboard and serial mouse Floppy Disk 1 x 3 5 high density floppy disk drive...

Page 4: ...9 Pin Entry Time Zone 3 Cardholder Authority Levels 3 Holidays 100 IN Reader Can be using LED Indication Lamp with Keypad OUT Reader Only LED Indication Lamp System Characteristics Multiple Technolog...

Page 5: ...232 RS485 Converter Modem Modem Telephone Line EXP 06E EXP 06E 1 32 RS232 RS485 Converter EXP 06E EXP 06E 1 32 E E D D D D Communication Configurations E Wire Label From To Function Gauge AWG No of Pa...

Page 6: ...ly 6 3 Single Pin Code Entry Only At this operation mode users can key in the card number through keypad instead of card operation Press key will enable this function if this operation is set If user...

Page 7: ...proximity card reader s LED light will hold on 5 seconds to green color user should release key 0 button in the keypad and key in 4 digits the current used pin code If the key in pin code is correct...

Page 8: ...code is 0001 then the duress pin code should be 0002 i e If the user pin code is 9999 then the duress pin code should be 0000 6 9 Double Pin Code Entry for Duress Pin Code If duress alarm function in...

Page 9: ...l The EXP 06E has two types of battery backup onboard memory and operational power The operational power battery known as the Advanced Power Supply APS gives the EXP 06E internal power fail capability...

Page 10: ...l diode parallel to the door lock 2 ATTENEION It may affect the performance of EXP 06E when diode is not installed parallel to the lock See Figure 1 2 7 3 3 Door Release Button Door Sensor 1 Connect o...

Page 11: ...ommunication using the RS 232C communication using the RS 485 communication protocol set jumpers JP4 JP5 to 1 2 position 7 4 2 RS 232C Connection Table Pin connection EXP 06E Pin Signal DB25 DB9 Host...

Page 12: ...r Model ic485Ip 1F Table Pin connection EXP 06E Pin Converter E 2 4 Sort F 1 3 Sort 7 5 Connection with Advanced Power Supply Option The Power Supply Board provides uninterrupted power backup of EXP 0...

Page 13: ...put the time sec at the Door Open Alarm field in Software and also connect the Door Sensor to the controller 3 Duress Alarm If the door is opened with key in the duress pin code the alarm relay will b...

Page 14: ...1 Memory 32KB Clock Data Memory back up battery Non charge 1 month backup during power failure Communication Interface RS232 and RS485Converter type Data Transfer Rate Local Remote 9 600 bps Input Vol...

Page 15: ...tput Alarm Relay Output IBM Compatible PC KEY PAD JP14 DATA 1 STROBE DATA 0 DATA BEEPER NOT USE CARD PRESENT LED GND VDC RAM Program Chip EXP 06E Controller Board CPU I O 2 I O 1 JP15 JP8 JP18 JP12 CO...

Reviews: