background image

ALCOLOCK FOCUS

3

CAMERA INSTALLATION

WIRING

1. 

Strip 1-2 cm (1/3” – 5/8”) off the wire ends of the ALCOLOCK Focus camera’s 

Power Harness Cable (13-001143).

2. 

Connect the BLACK wire to a ground source (GND).

3. 

Connect the RED wire to a source of 12V DC.

4. 

Connect the YELLOW (CANH) wire from the ALCOLOCK FOCUS camera Power 

Harness Cable to the YELLOW-RED wire from the ECU Harness Cable  

(13-001102).

5. 

Connect the BLUE (CANL) wire from the ALCOLOCK Focus camera Power 

Harness Cable to the BLUE-WHITE from the ECU harness cable.

6. 

Solder and seal heat-shrink (94-000251) over each soldered connection once the 

camera has been tested and confirmed to be functioning.

7. 

Insert the USB end of the ALCOLOCK Focus camera Power Harness Cable wire 

to the back of the camera. Tighten the tamper-proof screw and place seal over top.

MOUNTING CAMERA

1. 

Locate a flat area suitable for camera mounting where the camera will not obstruct 

the view of the driver.

2. 

Use alcohol wipes to clean the mounting area thoroughly.

3. 

Peel the backing off one side of the double-sided adhesive and stick it to the base 

of the camera.

4. 

Peel the backing off the other side of the double-sided adhesive and secure the 

camera to the prepared mounting location.

HANDSET INSTALL PROCEDURE WITH CAMERA

NOTE: The process detailed below should be completed concurrently with the “HS Install 

Procedure and ITE Install Transaction” process described in section 16.0 of the LR 

installation and services manual (60-000249). 

1. 

In the 

SERVICE

 menu, scroll to the 

Install

 option by pressing 

Prev

 or 

Next

, then 

press 

Select

2. 

The screen will display 

Do you want to install camera?

 Press 

Yes

.

3. 

Continue with the steps of a standard install procedure. At the end of the 

procedure, the LR screen should display a live feed from the ALCOLOCK Focus 

camera.

Summary of Contents for ALCOLOCK Focus

Page 1: ...Installation and services manual ALCOLOCK Focus TM...

Page 2: ...ternational Inc and are used under license Alcohol Countermeasure Systems is the trading style of Alcohol Countermeasure Systems Corp 2014 Alcohol Countermeasure Systems Corp The information disclosed...

Page 3: ...ns 1 Introduction 2 Required tools 2 ACS parts 2 Camera installation 3 Wiring 3 Mounting camera 3 Handset install procedure with camera 3 Setting the optimum camera angle 4 Monitoring 5 Camera removal...

Page 4: ...ALCOLOCK Focus camera before the vehicle electrical system has been inspected ALCOLOCK LR device ALCOLOCK Focus camera and all cabling must be positioned so as not to obstruct vehicle operation Keep...

Page 5: ...nstruction for the connection positioning removal and troubleshooting of the ALCOLOCK Focus camera 79 007553 The process outlined in this manual should be performed in conjunction with the correspondi...

Page 6: ...eal over top MOUNTING CAMERA 1 Locate a flat area suitable for camera mounting where the camera will not obstruct the view of the driver 2 Use alcohol wipes to clean the mounting area thoroughly 3 Pee...

Page 7: ...river s seat 3 Pivot the camera left and right at the base to centre the driver s head horizontally as in Fig 1 Confirm the correct position via the live feed on the handset screen 4 Tighten the two 2...

Page 8: ...nd standard in car procedure have been completed the handset screen will display Monitor Complete Connect to PC NOTE If the standard monitoring procedure is completed before the image transfer has com...

Page 9: ...4 Remove the USB drive and disconnect the handset Proceed with ITE Removal Transaction outlined in section 22 5 of the LR installation and services manual 60 000249 5 Remove heat shrink and unsolder...

Page 10: ...ct camera Camera is defective Camera is not connected Check connections between ECU and camera If problem persists use new camera and or ECU No image is displayed on the handset Camera optical system...

Page 11: ......

Page 12: ...INM ENG 60 000619 C 2014...