7.1.3.
SELECT_CARD_TYPE
This command sets the required card type. The firmware in the BioCARDKey adjusts the
communication protocol between reader and the inserted card according to the selected card type.
Command format
Instruction Code
Data length
Data
TYPE
02
H
01
H
TYPE
See Appendix A for the value to be specified in this command for a particular card to
be used.
Response data format
No
response
data
7.1.4.
RESET
This section describes the
RESET
command only for the case when no card type is selected or when
the card type 00
H
is selected. For all other cases, please refer to the specific section described for
each individual card type.
Command format
Instruction
Code
Data length
80
H
00
H
Response data format
ATR
ATR
The answer-to-reset string returned by the card.
The return status code for this command is 90 00
H
when the inserted card is a T=0 card and 90 01
H
when the inserted card is a T=1 card, otherwise the status code is 60 20
H
.
Document Title Here
Document Title Here
Document Title Here
AET60 Reference Manual
Version 1.7
Page 17 of 24
www.acs.com.hk