ACR3801 – Reference Manual
Version 2.01
www.acs.com.hk
Page 18 of 62
8.1.7.
PC_to_RDR_SetParameters
Sets slot parameters.
Offset
Field
Size
Value
Description
0
bMessageType
1
61h
-
1
dwLength
4
-
Size of extra bytes of this message
5
bSlot
1
-
Identifies the slot number for this
command
6
bSeq
1
-
Sequence number for command
7
bProtocolNum
1
-
Specifies what protocol data structure
follows:
00h = Structure for protocol T=0
01h = Structure for protocol T=1
The following values are reserved for
future use:
80h = Structure for 2-wire protocol
81h = Structure for 3-wire protocol
82h = Structure for I2C protocol
8
abRFU
2
-
Reserved for future use
10
abProtocolDataStructure
Byte
array
-
Protocol Data Structure
Protocol Data Structure for Protocol T=0 (
dwLength=
00000005h)
Offset
Field
Size
Value
Description
10
bmFindexDindex
1
-
B7-4 – FI – Index into the table 7 in
ISO/IEC 7816-3:1997 selecting a
clock rate conversion factor
B3-0 – DI - Index into the table 8 in
ISO/IEC 7816-3:1997 selecting a baud
rate conversion factor
11
bmTCCKST0
1
-
B0 – 0b, B7-2 – 000000b
B1 – Convention used (b1=0 for direct,
b1=1 for inverse) Note: The CCID
ignores this bit.
12
bGuardTimeT0
1
-
Extra Guardtime between two
characters. Add 0 to 254 etu to the
normal guardtime of 12etu. FFh is the
same as 00h.
13
bWaitingIntegerT0
1
-
WI for T=0 used to define WWT
14
bClockStop
1
-
ICC Clock Stop Support:
00h = Stopping the Clock is not
allowed
01h = Stop with Clock signal Low
02h = Stop with Clock signal High
03h = Stop with Clock either High or
Low