ACR1255U-J1 – Reference Manual
Version V1.01
www.acs.com.hk
Page 63 of 73
6.6.10.
Set PICC Operating Parameter
This command is used for setting the PICC operating parameter.
Note: The setting will be saved into non-volatile memory.
Set the PICC Operating Parameter Format (6 bytes)
Command
Class
INS
P1
P2
Lc
Data In
Set the PICC Operating
Parameter
E0h
00h
00h
20h
01h
Operation Parameter
Set the PICC Operating Parameter Response Format (6 bytes)
Response
Class
INS
P1
P2
Le
Data Out
Result
E1
00h
00h
00h
01h
Operation Parameter
Operating Parameter (1 byte)
Operating
Parameter
Parameter
Description
Option
Bit 0
ISO14443 Type A
The Tag Types to be detected during
PICC Polling.
1 = Detect
0 = Skip
Bit 1
ISO14443 Type B
1 = Detect
0 = Skip
Bit 2
Felica
1 = Detect
0 = Skip
Bit 3
RFU
RFU
RFU
Bit 4
Topaz
The Tag Types to be detected during
PICC Polling.
1 = Detect
0 = Skip
Bit 5 - 7
RFU
RFU
RFU
Note: Default value of Operation Parameter = 17h.