Response
HID Frame
Length (bytes)
Description
RspMessagType
1
Commands
Length
2
Data length
Slot
1
Default value: 00h
Seq
1
Sequence
Slot Status/Param
1
Slot Status/Parameter
Checksum
1
Checksum
Data
0-N
Data
Data checksum is used in detecting errors that may have been introduced during wireless data
transmission. To calculate the data checksum: XOR { RspMessageType, Length, Slot, Seq,
SlotStatus/Param, Data }.
Example:
62010063 => Checksum = 63h
5.6. Bluetooth Communication Protocol
ACR1255U-J1 communicates to the paired device using the Bluetooth interface with a predefined
protocol. The protocol is similar to the formats of the CCID Command Pipe and Response Pipe.
Command
Mode Supported
Sender
Description
62h
Authenticated
Paired device
PICC Power On
63h
Authenticated
Paired device
PICC Power Off
65h
Authenticated
Paired device
Get Card Status
6Fh
Authenticated
Paired device
Exchange APDU
6Bh
Authenticated
Paired device
Escape Commands
Table 6
: Command Code Summary
Command Mode Supported Sender
Description
80h
Authenticated
Reader Response to Data Block
81h
Authenticated
Reader Response to Slot Status
83h
Authenticated
Reader Response to Escape Command
50h
Authenticated
Reader Notify Card Status
51h
Authenticated
Reader Response to Hardware Error
Table 7
: Response Code Summary