Technical data
Materials
Membrane:
Ceramic AL
2
O
3
99,9%
(medium contact)
Steel 1.4404 (AISI 316L)
high temperature variant – type H
Probe:
Steel 1.4404 (AISI 316L) / 1.4571 (AISI 316Ti) /
(medium contact) navy bronze CU SN 12 / hastelloy C / PEEK
Carrying cable:
PE – polyethylene
(medium contact)
FEP – fluorinatedetylenepropylene
Tube prolongation: Steel 1.4404 (AISI 316L) / 1.4571 (AISI 316Ti)
(medium contact)
Process connection:
Steel 1.4404 (AISI 316L) / 1.4571 (AISI 316Ti) /
(medium contact)
navy bronze CU SN 12 / hastelloy C / PEEK
Steel 1.4435 (AISI 316L)
high temperature variant – type H
Connection housing:
POM – polyoxymethylene (Delrin
) / PP – polypropylene / CrNi-steel
Cable gland:
Housing PA – polyamide resp. CrNi-steel, gaskets CR / NBR
Device plug M12x1:
Socket CrNi-steel, insert PUR, contacts gold-plated
Pressure compens. element:
Housing PA – polyamide, membrane ePTFE
Gaskets:
medium contact
FPM – fluorelastomere (Viton
)
EPDM – etylene-propylene-dienmonomere
CR – chloroprene-rubber (Neopren
)
FFKM – perfluorelastomere (Kalrez
)
others
FPM – fluorelastomere (Viton
)
silicone
Environmental conditions
Environmental temperature:
– 20°C...+85°C, limitation at Ex variants
Limitation by variant
Environmental temperature range
Carrying cable
-20...+70°C
Limitation by material
Environmental temperature range
Connection housing PP
-10...+85°C
Process temperatures:
– 20°C...+125°C, limitation at Ex variants
Limitation / Extension by variant
Process temperature range
High temperature variant – Typ H
-10...+140°C
Carrying cable
-20...+70°C
Limitation by material
Process temperature range
Gasket CR
-20...+120°C
Gasket FFKM
-15...+125°C
Process pressure ranges:
depends on variant, maximum – 1 bar ...20 bar
Pressure transmitting liquid:
Vegetable oil
only at high temperature variant – type H
Vacuum- / overload resistance:
depends on meas. range, see table perm. pressure to the membrane
Weight:
depends on variant
Protection classification:
IP68
DIN EN 60529
Climatic classification:
4K4H
DIN EN 60721-3-4
Vibration classification:
4 g / 5 – 100 Hz
EM – compatibility:
emission
DIN EN 61326-1 operation device class B
immunity
DIN EN 61326-1 industrial range
Reference conditions:
DIN EN 60770-1
T = 25 °C, relative humidity 45...75 %,
environmental air pressure 860...1060 kPa