5.1. Switching on
Once the installation is complete, start the device by applying the voltage supply. Before, check once again
that all electrical connections are correct.
Starting sequence
For 1 second during the switching-on process, the segment test (
8 8 8 8 8
) is displayed followed by an
indication of the software type and, after that, also for 1 second the software version. After the starting
sequence, the device switches to operation/display mode.
5.2. Standard parameterisation:
(Flat operation level)
To parameterise the display, press the
[P]
-key in operating mode for 1 second. The display then changes to
the menu level with the first menu item
TYPE
.
5. Setting up the device
Menu level
Parameterisation level
Selection of the input signal,
tYPE
:
Default:
sens.f
There are 3 measuring input options available for known sensor sensibilities:
SENS.1
for 1mV/V,
SENS.2
for 2mV/V and
SENS.3
for 3.3mV/V. Each sensor is measured and calibrated up to 4mV/V
via
SEnS.F
. Confirm the selection with
[P]
and the display switches back to menu level.
Setting the end value of the measuring range,
END
:
Default:
10000
Set the end value from the smallest to the highest digit with
[
▲
] [
▼
]
and confirm each digit with
[P]
. A minus sign can only be parameterized on the highest value digit. After the last digit, the
display switches back to the menu level. If
Sens
was selected as input option, you can only
select between
noca
and
cal.
With
noca
, only the previously set display value is taken over, and
with
cal
, the device takes over both the display value and the analogue input value.
Setting up the measuring range start/offset value,
offs
:
Default:
0
Enter the start/offset value from the smallest to the highest digit with
[
▲
] [
▼
]
and confirm each
digit with
[P]
. After the last digit the display switches back to the menu level. If
Sens
was
selected as input option, you can only select between
noca
and
cal.
With
noca
, only the
previously set display value is taken over, and with
cal
, the device takes over both the display
value and the analogue input value.
Setting the decimal point,
dot
:
Default:
0
The decimal point on the display can be moved with
[
▲
] [
▼
]
and confirmed with
[P]
. The
display then switches back to the menu level again.
5. Setting up the device