ANR-DNV3N3 Series
47
4
3V3_UV_WARNING
VOUT < 3.0V = 1 ; Normal = 0
3
5V_OV_WARNING
VOUT > 5.5V = 1 ; Normal = 0
2
5V_OC_WARNING
5V_IOUT > Max Current of 110%@ 1Sec = 1 ;
Normal = 0
1
3V3_OV_WARNING
VOUT > 3.6V = 1 ; Normal = 0
0
3V3_OC_WARNING
3V3_IOUT > Max Current of 110%@ 1Sec = 1 ;
Normal = 0
Contents in B0h (PSU_STATUS) Command Code:
Bit Number
Status Bit Name
Meaning
[7:4]
Reserved
Return=0
3
PSU2 PRESENT
Module Plug OUT = 1 ; Module Plug IN = 0
2
PSU1 PRESENT
Module Plug OUT = 1 ; Module Plug IN = 0
1
PSU2 STATUS
FAIL = 1 ; OK = 0
0
PSU1 STATUS
FAIL = 1 ; OK = 0
MFR Meaning:
Command Code
Command Name
Meaning
99h
MFR_ID
ETASIS
9Ah
MFR_MODEL
EFRP-S2287HPM
9Bh
MFR_REVSION
A0 ~ Z9
9Eh
MFR_SERIAL
Code = 12 (ex. T201XXG00001)
A7h
MFR_POUT_MAX
280 (W)
A8h
MFR_TAMBIENT_MAX
40 (°C)
I
2
C Address Set Table:
PDB MCU Device
4A
FRU Device (Option)
AC
4.3.7. Chassis Opened
Syntax:
int get_chassis_open_status(void)
Description:
This function can get chassis status.
Parameters:
None.
Return Value:
0: Disabled, 1: Enabled.