ANR-DNV3N3 Series
43
Syntax:
Void get_lcm_firmware_ver( unsigned char *data)
Description:
This function can get LCM PIC Version.
Parameters:
lcm pic version will save the unsigned char pointer
parameters.
Return Value:
None.
Syntax:
Void set_lcm_default_graphic(void)
Description:
This function can set LCM setting to default.
Parameters:
None.
Return Value:
None.
4.3.5. Power Supply Unit (PMBUS)
Syntax:
float pmbus_read_vout_12V(void)
Description:
This function can get power supply unit Vout 12V.
Parameters:
None.
Return Value:
float Vout 12V
Syntax:
float pmbus_read_vout_3V3(void)
Description:
This function can get power supply unit Vout 3.3V.
Parameters:
None.
Return Value:
float Vout 3.3V
Syntax:
float pmbus_read_vout_5V(void)
Description:
This function can get power supply unit Vout 5V.
Parameters:
None.
Return Value:
float Vout 5V
Syntax:
int get_pmbus_psu_status(int psu)
Description:
This function can get which power supply unit status.
Parameters:
psu: 0-1
Return Value:
0: Good, 1: Fail